A rheometer was used to characterize the gelation rate of six commercial short- to medium-term (chairside intra-oral gelation) denture soft-lining materials. Shear puncture force was measured from one to 60 days for six short- to medium-term materials as well as for three heat-cured (polymerizable) materials. The observed increase in puncture force with age of the specimen was considered to be a function of increased polymer chain entanglement and/or loss of plasticizer. Reduction in puncture force with age occurred for some materials as a result of hydration of the polymer gel. Rheometer setting time (gelation rate) and puncture force values for the intra-oral gelation materials were influenced by the quantity of ethyl alcohol present in the mixing liquid. In general, the higher the level of ethyl alcohol, the shorter the gelation time and the stronger the gel. The characterization of the properties may help develop improved prosthodontic treatment procedures, and allow better management of soft-tissue recovery following trauma.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0109-5641(91)90061-3 | DOI Listing |
Ann Bot
January 2025
Seed Biology and Technology Group, Department of Biological Sciences, Royal Holloway University of London, TW20 0EX, Egham, United Kingdom.
The biomechanical, morphological and ecophysiological properties of plant seed/fruit structures are adaptations that support survival in unpredictable environments. High phenotypic variability of noxious and invasive weed species such as Raphanus raphanistrum (wild radish) allow diversification into new environmental niches. Dry indehiscent fruits (thick and lignified pericarp [fruit coat] enclosing seeds) have evolved many times independently.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou 730050, China.
Recent studies have identified microneedle (MN) arrays as promising alternatives for transdermal drug delivery. This study investigated the properties of novel staggered MN arrays design featuring two distinct heights of MNs. The staggered MN arrays were precisely fabricated via PμSL light-cured 3D printing technology.
View Article and Find Full Text PDFSci Rep
January 2025
School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing, 102488, China.
The main advantages of microneedles are precise drug delivery through human skin, minimal tissue damage and painlessness. We conducted structural analysis and skin puncture studies of hollow microneedles using ANSYS for three materials: Hafnium Dioxide (HfO), Polyglycolic acid (PGA) and Polylactic acid (PLA). Firstly, we selected three lengths, three tip diameters and three base diameters to conduct a L(3) orthogonal experiment.
View Article and Find Full Text PDFInt J Obstet Anesth
December 2024
Department of Biomedical Engineering and the School of Brain Sciences and Cognition, Ben Gurion University of the Negev, Beer Sheva, Israel.
Background: Correct identification of the epidural space requires extensive training for technical proficiency. This study explores a novel bimanual haptic simulator designed for the precise insertion of an epidural needle based on loss-of-resistance (LOR) detection, providing realistic dual-hand force feedback.
Methods: The simulator, equipped with two haptic devices connected to a Tuohy needle and an LOR syringe, was designed to simulate the tissues' resistive forces felt by the user during the procedure, offer anatomical variability and record detailed performance metrics for personalized feedback.
Purpose: The objective was to use cyclic tensile loading to compare the gap formation at suture site of three different suture materials to repair bovine radial meniscal tears: (1) polyglactin sutures, (2) tough adhesive puncture sealing (TAPS) sutures and (3) ultra-high molecular weight polyethylene (UHMWPE) sutures.
Methods: Twelve ex vivo bovine knees were dissected to retrieve the menisci. Complete radial tears were performed on 24 menisci, which were then separated into three groups and repaired using either pristine 2-0 polyglactin sutures, TAPS sutures (2-0 polyglactin sutures coated with adhesive chitosan/alginate hydrogels) or 2-0 UHMWPE sutures with a single stitch.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!