Comparison of commercially available disposable chemical hand and foot warmers.

Wilderness Environ Med

US Olympic Training Center, US Olympic Committee, Performance Services, Colorado Springs, CO 80909-5760, USA.

Published: May 2009

AI Article Synopsis

  • The study aimed to analyze the thermal behaviors of 14 different hand and foot warmers commonly used by winter sports athletes and outdoor enthusiasts.
  • Researchers used thermistors to monitor temperature and assessed variables such as peak temperature, time to reach it, and duration above 30 degrees Celsius, finding significant variability in performance among different brands and types.
  • Results indicated that some warmers exceeded their packaging claims while others did not, establishing a clear link between the mass of the warmers and how long they produced heat.

Article Abstract

Objective: Small chemical hand and foot warmers are used by many winter sport athletes and other outdoor enthusiasts. The purpose of this study was to characterize the thermal behaviors of 14 commercially available hand and foot warmers.

Methods: Both types of warmers were instrumented with a fast-responding thermistor. One of each pair of warmers was placed in a boot or glove. Temperature was recorded in a data logger for a period of hours to more than a day until the heat output of the devices ceased and returned to room temperature. Thermal behaviors were characterized and graphed, including peak temperature, time to peak temperature, and duration of temperature greater than 30 degrees C. Reliability was determined by comparing thermal behavior of 2 hand or foot warmers of the same type and from the same manufacturer. Comparisons were also made between package claims and measured behaviors.

Results: Measured outcomes were most noteworthy in their variability within and between manufacturers and types of warmers. A strong correlation was found between the masses of the warmers and their duration of heat production.

Conclusions: Although there is a paucity of research information on these types of warmers, this experiment showed that some of the devices exceeded packaging claims while others fell short; that the thermal behavior over time of the devices was variable; and that there appears to be a simple but strong relationship between the mass of the devices and the duration of their heat production.

Download full-text PDF

Source
http://dx.doi.org/10.1580/08-WEME-OR-243.1DOI Listing

Publication Analysis

Top Keywords

hand foot
16
foot warmers
12
types warmers
12
chemical hand
8
warmers
8
thermal behaviors
8
peak temperature
8
thermal behavior
8
duration heat
8
temperature
5

Similar Publications

Background: Tuberculous spondylitis (TS) and brucellar spondylitis (BS) exhibit certain similarities in clinical presentation and imaging characteristics, making differential diagnosis challenging. Developing a reliable differential diagnosis model can assist clinicians in distinguishing between these two conditions at an early stage, allowing for targeted prevention and treatment strategies.

Methods: Patients diagnosed with TS and BS were retrospectively collected and randomized into training and validation cohorts (ratio 7:3).

View Article and Find Full Text PDF

Background: For patients with osteoporosis and rotator cuff tears, there is still no consensus on current treatment methods. The material, structure, and number of anchors have important effects on the repair outcome.

Purpose: To investigate the use of chitosan quaternary ammonium salt-coated nickel-titanium memory alloy (NTMA) anchors to treat rotator cuff injury in shoulders with osteoporosis in a rabbit osteoporosis model.

View Article and Find Full Text PDF

The purpose of this study was to investigate the effect of different times return to activity on tendon healing after Double Kessler method suture in rats with Achilles tendon rupture. The left Achilles tendon of 80 10-week-old rats was repaired. The rats were randomly divided into 4 groups: non-fixed group, fixed one week group, fixed two weeks group and fixed three weeks group.

View Article and Find Full Text PDF

Biodegradable PHBVHHx-PEG/Collagen Hydrogel Scaffolds for Cartilage Repair.

Tissue Eng Part A

January 2025

Department of Orthopedic Surgery and Orthopedic Research Institute, Sports Medicine Center, West China Hospital, Sichuan University, Chengdu, China.

Recently, there has been increased attention on the treatment of cartilage repair. Overall, we constructed PHBVHHx-COL, a composite hydrogel of PHBVHHx-co-PEG and collagen, and evaluated its cartilage repair efficacy through and studies using hydrogel loaded with peripheral blood-derived mesenchymal stem cells (PBMSCs). Rheological properties and compressive mechanical properties of the hydrogels were systematically evaluated.

View Article and Find Full Text PDF

Background: HFMD is a common infectious disease that is prevalent worldwide. In many provinces in China, there have been outbreaks and epidemics of whooping cough, posing a threat to public health.

Purpose: It is crucial to grasp the epidemiological characteristics of HFMD in Quzhou and establish a prediction model for HFMD to lay the foundation for early warning of HFMD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!