A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasound usage in the head and neck surgeon's office. | LitMetric

Ultrasound usage in the head and neck surgeon's office.

Curr Opin Otolaryngol Head Neck Surg

Department of Otorhinolaryngology, Head and Neck Surgery Nordstadt-Clinic, Academic Hospital, Hannover, Germany.

Published: April 2009

Purpose Of Review: To review the essential developments in neck sonography published in the past 12 months and to elucidate their influence on the indications and diagnostic accuracy of office-based ultrasonography.

Recent Findings: In the screening of the neck in patients with squamous cell carcinoma, sonographic and duplex sonographic characteristics have been described to identify lymph node metastases, that is, size, shape, echogenicity, homogeneity, absence of hilar sign and hilar vessel, surface irregularity, necrotic areas, evidence of extracapsular spread, peripheral perfusion pattern, focal vascularization defects, and high pulsatility index. The combination of conventional ultrasound, duplex sonography, and ultrasound-guided fine-needle aspiration biopsies (USgFNAB) achieves an overall accuracy of nearly 100%. Ultrasound has been found to be most accurate in the diagnosis and differential diagnosis of thyroid and parathyroid disorders, the localization of parathyroid adenomas and the differential diagnosis of thyroid gland disorder. Sonographic characteristics, however, are mostly unspecific. Sonography provides the chance to obtain cytologic material under direct view by USgFNAB.

Summary: Office-based ultrasonography is a simple and rewarding technique that is enhanced by the experience of the investigator. The neck surgeon who is caring for the patient might use this information for diagnostic and therapeutic management. Due to high accuracy, noninvasiveness, and lack of radiation exposure, ultrasonography is required in the diagnosis and differential diagnosis of any pathologic masses in the entire neck and prior to any surgical procedure. Future developments, that is, elastography, might lead to further improvement in the diagnostic accuracy to differentiate benign and malignant masses.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MOO.0b013e3283297042DOI Listing

Publication Analysis

Top Keywords

differential diagnosis
12
diagnostic accuracy
8
sonographic characteristics
8
diagnosis differential
8
diagnosis thyroid
8
neck
5
diagnosis
5
ultrasound usage
4
usage head
4
head neck
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!