Aims: The deleterious effects of right ventricular apex (RVA) pacing may offset the potential benefit of ventricular rate (VR) regularization during atrial fibrillation (AF). Recent studies suggested that right ventricular septal (RVS) pacing may prevent the potential deleterious effects of RVA pacing and enhance the VR regularization (VRR) with ventricular pacing due to closer proximity of the pacing site to the retrograde atrioventricular conduction.
Methods And Results: We randomized 24 patients with permanent AF and symptomatic bradycardia to undergo RVA (n = 12) or RVS (n = 12) pacing. A VRR algorithm was programmed for all patients at 6-month after implantation. All patients underwent 6 min hall walk (6MHW) to assess exercise capacity at 6, 12, and 24 months, and radionuclide ventriculography to determine left ventricular ejection fraction (LVEF) at 6 and 24 months. Baseline characteristics were comparable in both groups except pacing QRS duration was significantly shorter during RVS pacing than RVA pacing (132 +/- 4 vs. 151 +/- 6 ms, P = 0.012). In both groups, VRR significantly increased the percentage of ventricular pacing and reduced VR variability (P < 0.05) without increasing mean VR (P > 0.05). At 6 months, 6MHW and LVEF were comparable in patients with RVA and RVS pacing (P > 0.05). At 24 months, patients with RVA pacing had significant decreases in LVEF and 6MHW after VRR pacing (P < 0.05), whereas RVS pacing with VRR preserved LVEF and improved 6MHW (P < 0.05).
Conclusion: In patients with permanent AF, VRR pacing at RVS, but not at RVA, preserves LVEF and provides incremental benefit for exercise capacity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eup087 | DOI Listing |
J Cardiovasc Electrophysiol
December 2024
Division of Interventional Cardiology, Cardio - Thoracic Department, Azienda Ospedaliera Universitaria Senese, Siena, Italy.
J Cardiovasc Electrophysiol
September 2024
BIOTRONIK SE & Co. KG, Berlin, Germany.
The use of CRT-D devices with left ventricular (LV) sensing has created controversy about programming various parameters especially the left ventricular T wave protection (LVTP) designed to prevent the delivery of a pacing stimulus into the LV vulnerable period. Such devices are available from two manufacturers. This review focuses only on those provided by Biotronik.
View Article and Find Full Text PDFFront Cardiovasc Med
April 2024
Department of Cardiology, Cardiovascular Center, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Methods Mol Biol
April 2024
Department of Cardiac Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.
Decompensated right ventricular failure (RVF) in pulmonary hypertension (PH) is fatal, with limited medical treatment options. Developing and testing novel therapeutics for PH requires a clinically relevant large animal model of increased pulmonary vascular resistance and RVF. This manuscript describes the method to induce an ovine PH-RVF model that utilizes left pulmonary artery (LPA) ligation, progressive main pulmonary artery (MPA) banding, and insertion of an RV pressure line for monitoring.
View Article and Find Full Text PDFPacing Clin Electrophysiol
April 2024
Research Department, Minneapolis Heart Institute East at United Hospital, St. Paul, Minnesota, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!