A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A rotating inlay decreases contact pressure on inlay post after posterior cruciate substituting total knee arthroplasty. | LitMetric

Background: The post/cam mechanism of posterior cruciate substituting total knee arthroplasty, which is intended to achieve maximum range of flexion, offers the risk of failure due to mechanical overload. The purpose of this in vitro study was to investigate load and contact pressure on the inlay post of posterior substituting knee prosthesis with different designs.

Methods: Isokinetic extension/flexion motions of seven fresh frozen left knee specimens were simulated dynamically in a specially designed knee simulator with an extension moment of 31 Nm. After implantation of the knee prosthesis system, which provides a fixed and a rotating posterior cruciate substituting inlay, a pressure sensitive film was fixed on the inlay post surface to measure maximum load and contact pressure.

Findings: Both types of inlays showed nearly the same contact load of up to 480 N on the posterior surface of the inlay post at 120 degrees knee flexion. Contact pressure was measured to be up to 19.7 MPa at 120 degrees flexion on the posterior surface of the post of the fixed inlay, whereas contact pressure was measured to be significantly lower (6.8 MPa, p=0.04) on the inlay post of the rotating inlay.

Interpretation: The modification of a rotating posterior cruciate substituting inlay could not decrease the horizontal load, but offers the possibility to decrease contact pressure on the inlay post to avoid mechanical overload of the polyethylene inlay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2009.03.006DOI Listing

Publication Analysis

Top Keywords

inlay post
24
contact pressure
20
posterior cruciate
16
cruciate substituting
16
pressure inlay
12
inlay
10
post posterior
8
substituting total
8
total knee
8
knee arthroplasty
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!