Background: Although high defibrillation threshold (DFT) is a major and unavoidable clinical problem after implantation of an implantable cardioverter defibrillator (ICD), little is known about the cause and management of a high DFT in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the predictors of a high DFT in patients with HCM.

Methods And Results: Twenty-three patients with non-dilated HCM who underwent ICD implantation were included. The DFT at the time of the device implantation was measured in all patients. The patients were divided into 2 groups, a high DFT group (DFT >or=15J, n=13) and a low DFT group (DFT <15J, n=10); and their baseline characteristics were compared. The QRS duration was longer in the high than in the low DFT group (128 +/-31 vs 103 +/-12 ms, respectively; P=0.02). QRS duration, left ventricular (LV) end-systolic diameter, and LV ejection fraction were significant predictors of DFT in univariate analysis. However, in multivariate analysis, the only factor significantly associated with DFT was QRS duration (P=0.002).

Conclusions: QRS duration is the most consistent predictor of a high DFT in HCM patients undergoing ICD implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.cj-08-0744DOI Listing

Publication Analysis

Top Keywords

high dft
12
high defibrillation
8
patients hypertrophic
8
hypertrophic cardiomyopathy
8
dft
8
dft patients
8
dft group
8
group dft
8
patients
6
high
5

Similar Publications

Insights into the adsorption mechanisms of VOCs molecules on non-oxidized and oxidized SnO (110) monolayer: DFT analysis.

J Mol Model

January 2025

Laboratory of Nanostructures and Advanced Materials, Mechanics and Thermofluids, Faculty of Sciences and Technologies, Hassan II University of Casablanca, B.P 146, 20650, Mohammedia, Morocco.

Context: Designing efficient sensitive materials for the detection of volatile organic compounds (VOCs) such as ethanol, acetone, and benzene is stringent owing to the significant environmental and health risks induced by these compounds, in addition to their role as biomarkers for chronic diseases and food quality. This study investigates the adsorption mechanisms of VOC molecules (ethanol, acetone, and benzene) on both non-oxidized and oxidized SnO (110) monolayers and identifies the most suitable surface for gas sensing applications. For this, we examined structural properties, adsorption energies, density of states, gas responses, and recovery times.

View Article and Find Full Text PDF

The chemical reduction of a pyracylene-hexa--hexabenzocoronene-(HBC)-fused nanographene TPP was investigated with K and Rb metals to reveal its multi-electron acceptor abilities. The reaction of TPP with the above alkali metals, monitored by UV-vis-NIR and H NMR spectroscopy, evidenced the stepwise reduction process. The use of different solvents and secondary ligands enabled isolation of single crystals of three different reduced states of TPP with 1, 2, and 3 electrons added to its π-system.

View Article and Find Full Text PDF

This study examines the intricate area of refractory-based high entropy alloys (RHEAs), focusing on a series of complex compositions involving nine diverse refractory elements: Ti, V, Cr, Zr, Nb, Mo, Hf, Ta, and W. We investigate the phase stability, bonding interactions, electronic structures, lattice distortions, mechanical, and thermal properties of six RHEAs with varying elemental ratios using VASP and OLCAO DFT calculations. Through comprehensive analysis, we investigate the impact of elemental variations on the electronic structure, interacting bond dynamics, lattice distortion, thermodynamic, mechanical, and thermal properties within these RHEAs, providing an insight into how these specific elemental variations in composition give rise to changes in the calculated properties in ways that would guide future experimental and computational efforts.

View Article and Find Full Text PDF

For weakly interacting adsorbate/substrate systems, the integer charge transfer (ICT) model describes how charge transfer across interfaces depends on the substrate work function. In particular, work function regimes where no charge transfer occurs (vacuum level alignment) can be distinguished from regions where integer charge transfer by electron tunneling from substrate to adsorbate or vice versa takes place (Fermi level pinning). While the formation of singly integer charged molecular anions and cations of organic semiconductors on various substrates has been well described by this model, the double integer charging regime has so far remained unexplored and experimentally elusive.

View Article and Find Full Text PDF

Using NMR Spectroscopy to Evaluate Metal-Ligand Bond Covalency for the f Elements.

Acc Chem Res

January 2025

Department of Chemistry, University at Buffalo, State University of New York, Buffalo, New York 14260, United States.

ConspectusUnderstanding f element-ligand covalency is at the center of efforts to design new separations schemes for spent nuclear fuel, and is therefore of signficant fundamental and practical importance. Considerable effort has been invested into quantifying covalency in f element-ligand bonding. Over the past decade, numerous studies have employed a variety of techniques to study covalency, including XANES, EPR, and optical spectroscopies, as well as X-ray crystallography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!