A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. | LitMetric

Objectives: The purpose of this study was to compare myocardial perfusion imaging (MPI) with high-speed single-photon emission computed tomography (SPECT) with conventional SPECT imaging for the evaluation of myocardial perfusion in patients with known or suspected coronary artery disease.

Background: A novel technology has been developed for high-speed SPECT MPI by employing a bank of independently controlled detector columns with large-hole tungsten collimators and multiple cadmium zinc telluride crystal arrays.

Methods: A total of 44 patients (39 men) underwent same-day Tc-99m sestamibi stress/rest MPI. High-speed SPECT images were performed within 30 min after conventional SPECT. Stress and rest acquisition times were 16 and 12 min for conventional imaging and 4 and 2 min for high-speed SPECT, respectively. Myocardial counts/min (cpm) were calculated for both conventional SPECT and high-speed SPECT. Images were visually analyzed, and the summed stress score (SSS) and summed rest score (SRS) were calculated. Image quality and diagnostic confidence were qualitatively assessed.

Results: High-speed SPECT SSS and SRS correlated linearly with conventional SPECT respective scores (r = 0.93, p < 0.0001 for SSS, and r = 0.93, p < 0.0001 for SRS). Image quality was rated good and higher in 17 (94%) cases for high-speed SPECT and 16 (89%) cases for conventional SPECT. Of the 44 patients studied, 36 (81.8%) and 35 (79.5%) were diagnosed definitely normal or abnormal by conventional and high-speed SPECT, respectively (p = NS). Myocardial count rate was significantly higher in high-speed versus conventional SPECT (384 x 10(-3) +/- 134 x 10(-3) cpm/min vs. 47 x 10(-3) +/- 14 x 10(-3) cpm/min, respectively, p < 0.0001) for stress and (962 x 10(-3) +/- 426 x 10(-3) cpm/min vs. 136 x 10(-3) +/- 37 x 10(-3) cpm/min, respectively, p < 0.001) for rest.

Conclusions: High-speed SPECT provides fast MPI with high image quality and up to 8 times increased system sensitivity. The amount of perfusion abnormality visualized by high-speed SPECT is highly correlated to conventional SPECT, with an equivalent level of diagnostic confidence.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2007.12.004DOI Listing

Publication Analysis

Top Keywords

high-speed spect
36
conventional spect
28
spect
17
10-3 +/-
16
10-3 cpm/min
16
high-speed
12
myocardial perfusion
12
image quality
12
conventional
10
perfusion imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!