Single level axial lumbar interbody fusion (AxiaLIF) using a transsacral rod through a paracoccygeal approach has been developed with promising early clinical results and biomechanical stability. Recently, the transsacral rod has been extended to perform a two-level fusion at both L4-L5 and L5-S1 levels (AxiaLIF II). No biomechanical studies have been conducted on multilevel fusion using the AxiaLIF technique. In this study, the biomechanics of L4-S1 motion segments instrumented with the AxiaLIF II transsacral rod was evaluated. Six human cadaveric lumbosacral spine segments from L4 to S1 were used (age ranges 46-74 years). Unconstrained and non-destructive pure moments in axial torsion, lateral bending, and flexion extension were applied to each specimen following intact, standalone AxiaLIF II, and AxiaLIF II with two posterior fixation options: facet screws and pedicle screws with rods. Range of motion was calculated from the raw data collected with an optical motion tracking system. The two-level transsacral rod was successfully inserted in all the specimens. At L4-L5 level in axial torsion (AT) and flexion extension (FE), none of the surgical treatments showed statistically significant difference between the procedures (all P > 0.05) although facet screws and pedicle screws had higher stability on average. In lateral bending (LB), the two posterior fixation techniques had significantly higher construct stability (P < 0.05) than the standalone rod. No significant difference was found between facet screws and pedicle screws (P = 0.821). At L5-S1 level in AT and LB, none of the surgical treatments were found to be statistically significant (all P > 0.05). In FE, standalone two-level transsacral rod had significantly higher range of motion (ROM) compared with the posterior fixation techniques (P < 0.05). In conclusion, the standalone rod reduced intact ROM significantly. Supplementary fixations including facet screws and pedicle screws are required to achieve higher construct stability for successful fusion. Further clinical studies are essential to evaluate the practical success of this technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2899656PMC
http://dx.doi.org/10.1007/s00586-009-0953-5DOI Listing

Publication Analysis

Top Keywords

transsacral rod
20
facet screws
16
screws pedicle
16
pedicle screws
16
posterior fixation
12
axialif technique
8
level axial
8
fusion axialif
8
axialif transsacral
8
axial torsion
8

Similar Publications

Compressive effect and collapse behavior of three different transsacral implants in sacral fragility fractures - a retrospective analysis of 106 cases.

Eur J Trauma Emerg Surg

December 2024

Department of Trauma and Reconstructive Surgery, BG Klinikum Bergmannstrost Halle gGmbH, Merseburger Strasse 165, 06120, Halle (Saale), Germany.

Purpose: The aim of this study were the retrospective evaluation of the compressive effect and complication rates of transsacral stabilization of osteoporosis-associated sacral fragility fractures in 106 patients using three different implants (6.0 mm sacral bar, n = 32; 7.3 mm screw, n = 26; 7.

View Article and Find Full Text PDF

[Minimally invasive stabilization of fragility fractures of the pelvis with transsacral bar and retrograde transpubic screw].

Oper Orthop Traumatol

April 2022

Klinik für Orthopädie und Unfallchirurgie, Westpfalz Klinik Kaiserslautern, Hellmut-Hartert-Strasse 1, 67655, Kaiserslautern, Deutschland.

Objective: Stabilization of fragility fractures of the pelvis (FFP) using a minimally invasive technique. Insertion of a transsacral rod into the transsacral corridor of S1. Insertion of a retrograde transpubic screw through the superior branch of the pubic bone.

View Article and Find Full Text PDF

Background: The subcutaneous screw rod system, commonly known as the internal pelvic fixator (INFIX), is useful in managing unstable pelvic ring fractures. Conventional INFIX and transiliac-transsacral (TITS) screw techniques are performed using C-arm fluoroscopy. There have been problems with medical exposure and screw insertion accuracy with these techniques.

View Article and Find Full Text PDF

Background: High-grade L5-S1 spondylolisthesis is challenging to treat, and there is no standard recommended operative technique. The authors performed a systematic review of the literature evaluating the efficacy and safety of modern transsacral instrumentation techniques for high-grade L5-S1 spondylolisthesis.

Methods: A systematic PubMed search adherent to PRISMA guidelines included relevant clinical studies reporting transsacral instrumentation for high-grade L5-S1 spondylolisthesis in adult humans from 1980 onward.

View Article and Find Full Text PDF

When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

Eur J Trauma Emerg Surg

December 2015

Department of Orthopaedic Surgery, Orthopaedic Trauma Institute, University of California-San Francisco (UCSF)/San Francisco General Hospital, 2550 23rd Str., Bldg. 9, 2nd Floor, San Francisco, CA, 94110, USA.

Purpose: This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C).

Methods: An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2).

View Article and Find Full Text PDF