A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fabrication of nano-hydroxyapatite/collagen/osteonectin composites for bone graft applications. | LitMetric

Fabrication of nano-hydroxyapatite/collagen/osteonectin composites for bone graft applications.

Biomed Mater

Division of Bioengineering, Nanoscience and Nanotechnology Initiative, Faculty of Engineering, National University of Singapore, 117576, Singapore.

Published: April 2009

Mineralized type I collagen (collagen I) nanofibers and their nanofibril bundles make up the microstructure of natural bone tissue, which range from nanometers to micrometers. However, attempts to achieve this hierarchically assembled structure in vitro have been unsuccessful. In this study, we added osteonectin into the collagen I solution, either at a high or low weight ratio (osteonectin: collagen I = 1:30 or 1:90) before co-precipitation. Results indicated that spindle-like nano-hydroxyapatite (nano-HA) was deposited on collagen/osteonectin and pure osteonectin (control) groups. Furthermore, transmission electron microscope (TEM) and scanning electron microscope (SEM) results showed that the assembled mineralized fiber bundles were formed randomly at different levels from 50 nm, 250 nm to 1100 nm. However, when we replaced collagen I with collagen II, osteonectin addition did not induce the formation of mineralized fiber bundles. The participation of osteonectin in the assembly of the mineralized fibers could provide new insights into the novel mineralization function of osteonectin for bone development in vivo and advancing new biomimetic methods for bone graft applications.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1748-6041/4/2/025019DOI Listing

Publication Analysis

Top Keywords

bone graft
8
graft applications
8
collagen collagen
8
osteonectin collagen
8
electron microscope
8
mineralized fiber
8
fiber bundles
8
collagen
6
osteonectin
6
fabrication nano-hydroxyapatite/collagen/osteonectin
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!