Objective: The aim of the present study was to clinically evaluate the suitability of Definite Multibond and Definite ormocer resin composite for luting of Cergogold glass ceramic inlays in a two-center trial involving two dentists.
Methods: Thirty-nine patients received 98 Cergogold inlays with at least one inlay luted with Definite Multibond/Definite (n=45) and at least one inlay luted with Syntac/Variolink Ultra (n=53) in a split mouth design. Treatments were carried out in two private practices by two operators (Operator A: n=38; Operator B: n=60). Forty-four cavities required caries profunda treatment, 23 cavities exhibited no enamel at the cervical margin. At baseline (2 months), and after 6, 14, 27, and 51 months of clinical service, the restorations were investigated according to modified USPHS criteria.
Results: The drop-out rate was 3% after 4 years. After 48 months of clinical service, 21 restorations in 16 patients (9 luted with Definite, 12 with Variolink; 2 placed by operator A and 19 by operator B) had to be replaced due to inlay fracture (n=11), tooth fracture (n=4), hypersensitivities (n=3), or marginal gap formation (n=3). Seventy-seven inlays were in good condition (survival rate 89.9%, median survival time 4.2 years (95% confidence interval +/-0.25; survival analysis by Kaplan-Meier algorithm). Survival rate after 4 years was 97.4% for operator A, and 75.4% for operator B (p=0.002; Log Rank/Mantel-Cox) resulting in annual failure rates of 0.6% and 6.2%, respectively. The operators did not differently judge the clinical behaviour of the luting procedures (Mann-Whitney U-test, p>0.05). Independent of the operator and the used luting system, the following criteria significantly changed over time: color match, marginal integrity, tooth integrity, inlay integrity, sensitivity, hypersensitivity, and X-ray control (p<0.05; Friedman test). Significant differences between operators over the whole period were computed for the criteria marginal integrity, tooth integrity, and inlay integrity (p<0.05, Mann-Whitney test). Differences between luting materials were only present during single recalls.
Significances: For luting of ceramic inlays, only slight differences between the two luting systems were detectable. The operator influence on clinical outcome was clearly proven.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.dental.2009.02.002 | DOI Listing |
JMIR Form Res
January 2025
Northwestern Medicine, Chicago, IL, United States.
Background: Patient recruitment and data management are laborious, resource-intensive aspects of clinical research that often dictate whether the successful completion of studies is possible. Technological advances present opportunities for streamlining these processes, thus improving completion rates for clinical research studies.
Objective: This paper aims to demonstrate how technological adjuncts can enhance clinical research processes via automation and digital integration.
JAMA Surg
January 2025
Department of Anesthesiology, University of Virginia School of Medicine, Charlottesville.
JAMA Dermatol
January 2025
Department of Dermatology, School of Medicine, University of North Carolina at Chapel Hill.
Importance: Surgery is frequently required for hidradenitis suppurativa (HS) treatment, but the impact of common comorbidities such as obesity, diabetes, and smoking on outcomes has been sparsely studied.
Observations: A total of 12 studies met final inclusion criteria for investigating complication rates associated with at least 1 comorbidity. Complication rates were associated with obesity in 3 of 10 studies.
Phys Rev Lett
December 2024
New York University, Center for Cosmology and Particle Physics, New York, New York 10003, USA.
We introduce an effective field theory (EFT) for conformal impurity by considering a pair of transversely displaced impurities and integrating out modes with mass inversely proportional to the separation distance. This EFT captures the universal signature of the impurity seen by a heavy local operator. We focus on the case of conformal boundaries and derive universal formulas from this EFT for the boundary structure constants at high energy.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
The Australian National University, Department of Quantum Science and Technology, Canberra, Australian Capital Territory 2601, Australia.
We demonstrate an atom interferometer measurement protocol compatible with operation on a dynamic platform. Our method employs two open interferometers, derived from the same atomic source, with different interrogation times to eliminate initial velocity dependence while retaining precision, accuracy, and long term stability. We validate the protocol by measuring gravitational tides, achieving a precision of 4.