A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and effectiveness of Realize adjustable gastric band: 3-year prospective study in the United States. | LitMetric

Background: The effectiveness and safety of bariatric surgery using laparoscopic adjustable gastric bands have been demonstrated in numerous published studies. We present the results of the first U.S. multicenter trial of the Realize adjustable gastric band, a laparoscopic adjustable gastric band previously available only outside the United States as the Swedish adjustable gastric band.

Methods: A total of 405 morbidly obese patients were screened at 12 different centers from May to November 2003 to participate in a prospective, single-arm study of the safety and effectiveness of the laparoscopically implanted Realize band. Changes in excess body weight, the parameters of diabetes and dyslipidemia, and the incidence of complications were assessed at 3 years of follow-up.

Results: Of the 405 patients, 276 (78.3% women and 61.2% white) qualified for the study. The average age was 38.6 + or - 9.4 years (range 18-61), and the preoperative body mass index was 44.5 + or - 4.7 kg/m(2). The mean hospital stay was 1.2 + or - 1.3 days. At 3 years, the average excess weight loss was 41.1% + or - 25.1% or a decrease in the body mass index of 8.2 kg/m(2) (18.6%) (P < .001). In diabetic patients with a baseline elevated hemoglobin A(1)c level, the level decreased by 1% (P < .001). The total cholesterol, low-density lipoprotein cholesterol, and triglycerides decreased by 9%, 16%, and 50%, respectively (P < .001), and the high-density lipoprotein cholesterol increased by 25% (P < .001) in patients with abnormal baseline values. One patient required conversion to an open surgical technique. No 30-day mortality occurred. The complication frequencies were generally low and included esophageal dysmotility in 0.4%, late balloon failure in 0.4%, band erosion in 0.4%, slippage in 3.3%, esophageal dilation in 3.3%, pouch dilation in 3.6%, catheter kinking in 1.1%, port displacement in 2.5%, and port disconnection in 4.3%. Reoperations were required in 15.2% of the patients and involved 2 band replacements, 9 band revisions, 5 port replacements, 22 port revisions, and 4 explants.

Conclusion: The results of our study have shown that the Realize adjustable gastric band is safe and effective in a diverse U.S. population of morbidly obese patients. Significant weight loss was achieved throughout the 3 years of follow-up, with corresponding improvements in the indicators of diabetes and dyslipidemia.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.soard.2008.12.007DOI Listing

Publication Analysis

Top Keywords

adjustable gastric
24
gastric band
16
realize adjustable
12
safety effectiveness
8
band
8
united states
8
laparoscopic adjustable
8
morbidly obese
8
obese patients
8
diabetes dyslipidemia
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!