All-terahertz fiber-scanning near-field microscopy.

Opt Lett

Department of Electrical Engineering and Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.

Published: April 2009

We demonstrate a room-temperature-operated all-terahertz (THz) fiber-scanning near-field imaging system. The upright-type THz near-field microscope has a compact size, capable of being integrated with an optical microscope. This transmission illumination near-field system could be a promising tool to distinguish breast cancer from the normal tissue without pathologic staining.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.34.001084DOI Listing

Publication Analysis

Top Keywords

fiber-scanning near-field
8
all-terahertz fiber-scanning
4
near-field
4
near-field microscopy
4
microscopy demonstrate
4
demonstrate room-temperature-operated
4
room-temperature-operated all-terahertz
4
all-terahertz thz
4
thz fiber-scanning
4
near-field imaging
4

Similar Publications

A hybrid scanning tunneling/optical near-field microscope is presented, in which an optical fiber tip coated with 100 nm thick Ag/Cr films scans the surface. The tip metallization enables operating the instrument via a current-based distance control and guarantees sub-nanometer spatial resolution in the topographic channel. The fiber tip simultaneously serves as nanoscale light source, given the optical transparency of the metal coating.

View Article and Find Full Text PDF

Performance of THz fiber-scanning near-field microscopy to diagnose breast tumors.

Opt Express

September 2011

Department of Electrical Engineering and Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, 10617, Taiwan.

Based on tissues from 20 female patients (mean age: 53 years; rang: 36-72 years), we examine the performance of a room-temperature-operated terahertz (THz) fiber-scanning near-field microscopy to diagnose slices of breast tissues. The specimens were frozen sliced and then measured in a thawed state without dehydration. We performed the imaging at 320 GHz.

View Article and Find Full Text PDF

All-terahertz fiber-scanning near-field microscopy.

Opt Lett

April 2009

Department of Electrical Engineering and Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.

We demonstrate a room-temperature-operated all-terahertz (THz) fiber-scanning near-field imaging system. The upright-type THz near-field microscope has a compact size, capable of being integrated with an optical microscope. This transmission illumination near-field system could be a promising tool to distinguish breast cancer from the normal tissue without pathologic staining.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!