The development of diffuse optical tomography (DOT) instrumentation for neuroimaging of humans is challenging due to the large size and the geometry of the head and the desire to distinguish signals at different depths. One approach to this problem is to use dense imaging arrays that incorporate measurements at different source-detector distances. We previously developed a high-density DOT system that is able to obtain retinotopic measurements in agreement with functional magnetic resonance imaging and positron emission tomography. Further extension of high-density DOT neuroimaging necessitates a thorough study of the measurement and imaging sensitivity that incorporates the complex geometry of the head--including the head curvature and layered tissue structure. We present numerical simulations using a finite element model of the adult head to study the sensitivity of the measured signal as a function of the imaging array and data sampling strategy. Specifically, we quantify the imaging sensitivity available within the brain (including depths beyond superficial cortical gyri) as a function of increasing the maximum source-detector separation included in the data. Through the use of depth related sensitivity analysis, it is shown that for a rectangular grid [with 1.3 cm first nearest neighbor (NN) spacing], second NN measurements are sufficient to record absorption changes along the surface of the brain's cortical gyri (brain tissue depth <5 mm). The use of fourth and fifth NN measurements would permit imaging down into the cortical sulci (brain tissue depth >15 mm).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8050954PMC
http://dx.doi.org/10.1364/ao.48.00d137DOI Listing

Publication Analysis

Top Keywords

depth sensitivity
8
dense imaging
8
imaging arrays
8
diffuse optical
8
optical tomography
8
high-density dot
8
imaging sensitivity
8
cortical gyri
8
imaging
6
sensitivity image
4

Similar Publications

Mesoporous silica nanoparticles (MSNPs) are promising nanomedicine vehicles due to their biocompatibility and ability to carry large cargoes. It is critical in nanomedicine development to be able to map their uptake in cells, including distinguishing surface associated MSNPs from those that are embedded or internalized into cells. Conventional nanoscale imaging techniques, such as electron and fluorescence microscopies, however, generally require the use of stains and labels to image both the biological material and the nanomedicines, which can interfere with the biological processes at play.

View Article and Find Full Text PDF

Applications of Deep Neural Networks with Fractal Structure and Attention Blocks for 2D and 3D Brain Tumor Segmentation.

J Stat Theory Pract

September 2024

Statistics Online Computational Resource, University of Michigan, 426 North Ingalls Str, Ann Arbor, Michigan 48109-2003.

In this paper, we propose a novel deep neural network (DNN) architecture with fractal structure and attention blocks. The new method is tested to identify and segment 2D and 3D brain tumor masks in normal and pathological neuroimaging data. To circumvent the problem of limited 3D volumetric datasets with raw and ground truth tumor masks, we utilized data augmentation using affine transformations to significantly expand the training data prior to estimating the network model parameters.

View Article and Find Full Text PDF

This study explores Ultra-Orthodox Jewish women's attitudes toward video-consultation usage in Israeli primary care settings. In-depth interviews were conducted with twenty-two women from diverse Ultra-Orthodox communities in Israel, using interpretative phenomenological analysis. Despite traditionally limited digital tool usage, participants showed readiness for video-consultations' adoption through dedicated 'kosher' medical devices.

View Article and Find Full Text PDF

Study on jet dynamic impact performance under the influence of standoff.

Sci Rep

December 2024

School of Mechanical and Electrical Engineering, North University of China, Taiyuan, 030051, Shanxi, China.

Due to the sensitivity of the shaped charge jet to standoff and the complexity of its impact under lateral disturbances, this study aims to investigate the dynamic impact evolution of the jet influenced by standoff and lateral disturbances. A finite element model for the dynamic impact of shaped charge jets was established. Dynamic impact experiments were designed and conducted to validate the effectiveness of the numerical simulations.

View Article and Find Full Text PDF

This study aimed to investigate the correlation between baseline MRI features and baseline carcinoembryonic antigen (CEA) expression status in rectal cancer patients. A training cohort of 168 rectal cancer patients from Center 1 and an external validation cohort of 75 rectal cancer patients from Center 2 were collected. A nomogram was constructed based on the training cohort and validated using the external validation cohort to predict high baseline CEA expression in rectal cancer patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!