Objectives: We developed a prosthesis for open pleurostomy cases where pulmonary decortication is not indicated, or where post-pneumonectomy space infection occurs. The open pleural window procedure not only creates a large hole in the chest wall that is shocking to patients, also results in a permanent deformation of the thorax. prosthesis for open pleurostomy is a self-retained silicone tube that requires the removal of 3 cm of one rib for insertion, and acts as a mature conventional open pleural window. Herein, we report our 13-year experience with this device in the management of different kinds of pleural empyema.
Methods: Forty-four consecutive patients with chronic empyema were treated. The etiology of empyema was diverse: pneumonia, 20; lung resections, 12 (pneumonectomies, 7; lobectomies, 4; non-anatomical, 1); mixed-tuberculous, 6; and mixed-malignant pleural effusion, 6. After debridement of both pleural surfaces, the prosthesis for open pleurostomy was inserted and attached to a small recipient plastic bag.
Results: Infection control was achieved in 20/20 (100%) of the parapneumonic empyemas, in 3/4 (75%) of post-lobectomies, in 6/7 (85%) of post-pneumonectomies, in 6/6 (100%) of mixed-tuberculous cases, and in 4/6 (83%) of mixed-malignant cases. Lung re-expansion was also successful in 93%, 75%, 33%, and 40% of the groups, respectively
Conclusions: Prosthesis for open pleurostomy insertion is a minimally invasive procedure that can be as effective as conventional open pleural window for management of chronic empyemas. Thus, we propose that the use of prosthesis for open pleurostomy should replace the conventional method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2666462 | PMC |
http://dx.doi.org/10.1590/s1807-59322009000300010 | DOI Listing |
Eur J Trauma Emerg Surg
January 2025
Dr C Lal Hospital, Ambala Cantt, Haryana, 133001, India.
Purpose: Tibial open shaft fractures are very common and susceptible to infection, which can lead to significant morbidity especially infection and non-union. Antibiotic coated nail is one option for fixing open shaft tibial fractures to minimise infection. This study aimed to compare the clinical outcome of Gentamicin-coated tibial nails versus regular unreamed interlocking tibial nails in the treatment of type I and II tibial open fractures.
View Article and Find Full Text PDFJ Clin Med
January 2025
PhD Program and Center of Morphological and Surgical Research (CEMyQ), Universidad de La Frontera, Temuco 4811230, Chile.
: This study aims to describe and analyze the indications and clinical results of total TMJ replacement in participants with degenerative and/or inflammatory joint diseases, defining patient and intervention conditions. : A systematic review was conducted according to the Cochrane Handbook for Systematic Reviews of Intervention and reported according to the PRISMA Items update. The search strategy was from 1997 to July 2024 in Pubmed, Embase, Scopus, and Web of Science.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Bowen University Teaching Hospital, P. O. Box 15, Ogbomoso, Oyo State, Nigeria.
Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.
Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.
PLoS One
January 2025
Department of Orthopedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland.
Background: Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.
Methods: This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!