Purpose: To determine with comparison of two different monopolar radiofrequency (RF) devices whether a longer duration of energy application has an effect on coagulation necrosis in ex vivo bovine liver tissue.

Materials And Methods: The volume and short- and long-axis diameters of the coagulation were assessed in ex vivo bovine livers after RF application for 5-60 minutes. A power of 60 W was used for the single perfusion applicator (n = 48), and a power of 200 W was used for the internally cooled cluster applicator (n = 48). Reproducibility and coagulation shape were assessed and compared. For statistical evaluation, the mean values of the dimensions were compared by using analysis of variance with the following factors: applicator, RF duration, and their interaction.

Results: RF application up to 60 minutes produced a mean maximum volume of coagulation of 116.8 cm(3)(95% confidence interval [CI]: 98.4 cm(3), 138.8 cm(3)) for the single perfusion device and 89.5 cm(3)(95% CI: 75.4 cm(3), 106.3 cm(3)) for the internally cooled cluster applicator. For both devices, duration of energy application up to 60 minutes showed a significant interaction for the volume and the short- and long-axis diameters of coagulation (P < .0001). The volumes of coagulation necrosis induced with the internally cooled cluster applicator were more reproducible than those induced with the single perfusion applicator (P < .0001). The shape of the lesion was closer to a sphere (mean shape ratio, 0.98) for the internally cooled cluster than for the single perfusion applicator (mean shape ratio, 1.21) (P < .0001).

Conclusions: There is a significant interaction between RF duration and both RF devices influencing the dimensions of coagulation. Longer durations of energy application expand the volume of coagulation with a better reproducibility and more spherical shape of coagulation for the internally cooled cluster device.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2009.01.003DOI Listing

Publication Analysis

Top Keywords

internally cooled
24
cooled cluster
24
single perfusion
20
energy application
16
duration energy
12
perfusion applicator
12
cluster applicator
12
coagulation
9
perfusion device
8
cluster device
8

Similar Publications

Greenhouse gas (GHG) emissions are creating unprecedented climate-driven extreme weather, with levels of heat and humidity surpassing human physiological tolerance for heat stress. These conditions create a risk of mass casualties, with some populations particularly vulnerable due to physiological, behavioural and socioeconomic conditions (eg, lack of adequate shelter, limited healthcare infrastructure, sparse air conditioning access and electrical grid vulnerabilities). Children, especially young children, are uniquely vulnerable to extreme heat-related morbidity and mortality due to factors including low body mass, high metabolism, suboptimal thermoregulatory mechanisms and behavioural vulnerabilities.

View Article and Find Full Text PDF

Background: Reversed shoulder arthroplasty (rTSA) is often used to restore functionality in patients with joint arthropathy and dysfunctional rotator cuff. As rTSA changes the biomechanical properties of the shoulder, an altered movement pattern of arm and scapula is to be expected. Previous studies focused on changes of the scapulohumeral rhythm during functional elevation tasks.

View Article and Find Full Text PDF

The first ground-state rotational spectrum of 3-methylstyrene (3MS) was measured by Fourier transform microwave spectroscopy under supersonic jet-cooled conditions. Transitions were assigned for two conformers: cis-3MS and trans-3MS. In the cis conformer, the vinyl group is oriented toward the methyl group, while in the trans conformer, it is positioned away from the methyl.

View Article and Find Full Text PDF

Since the initial publication on the first TiCT MXene in 2011, there has been a significant increase in the number of reports on applications of MXenes in various domains. MXenes have emerged as highly promising materials for various biomedical applications, including photothermal therapy (PTT), drug delivery, diagnostic imaging, and biosensing, owing to their fascinating conductivity, mechanical strength, biocompatibility and hydrophilicity. Through surface modification, MXenes can mitigate cytotoxicity, enhance biological stability, and improve histocompatibility, thereby enabling their potential use in biomedical applications.

View Article and Find Full Text PDF

Multiple Exciton Generation on Doped Wide-Band Semiconductor Photoanode with Hierarchical Quantum Structure.

Small

January 2025

Key Laboratory of Wide Bandgap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an, 710071, China.

The multiple exciton generation (MEG) effect, which produces multiple photo-generated charge carriers from a single high-energy photon absorption by a semiconductor with a narrow bandgap, has the potential to revolutionize photovoltaic, photoelectric detection, and other technologies. Here, this work finds that the surface carbon-modified wide-bandgap photoanode with hierarchical quantum structure can drive a photoelectrochemical reaction with a quantum efficiency exceeding 145% by the first time. More studies reveal that the presence of the MEG effect in the MEG-CdS photoanode is attributed to the formation of high-quality surface C-modified CdS quantum nanosheets on CdS bulk film by in situ, this hierarchical quantum structure leads to quantum confinement effects that increase effective Coulomb interaction for driving MEG and decrease competition for thermal exciton cooling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!