Purpose: To test the hypothesis that right enlargement assessed from right ventricular/left ventricular (RV/LV) dimension ratios of computed tomographic (CT) angiograms are equivalent irrespective of whether measured on axial views or reconstructed 4-chamber views.

Methods: RV/LV dimension ratios were calculated from measurements on axial views, manually reconstructed 4-chamber views and computer generated reconstructed 4-chamber views of CT angiograms in 152 patients with PE.

Results: Paired readings of the axial view and manually reconstructed 4-chamber view showed agreement with RV/LV > or =1 or RV/LV <1 in 114 of 127 (89.8%). Paired readings also showed agreement in 119 of 127 (93.7%) with axial views and computer generated reconstructed 4-chamber views. The McNemar test showed no statistically significant difference between assessments of RV enlargement (RV/LV > or = 1) with any method.

Conclusion: Right ventricular enlargement can be determined from axial views on CT angiograms, which are readily and immediately available, without obtaining 4-chamber reconstructed views.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11239-009-0331-5DOI Listing

Publication Analysis

Top Keywords

reconstructed 4-chamber
20
4-chamber views
12
axial views
12
ventricular enlargement
8
rv/lv dimension
8
dimension ratios
8
manually reconstructed
8
views angiograms
8
views
7
reconstructed
6

Similar Publications

Objectives: To compare standard-resolution balanced steady-state free precession (bSSFP) cine images with cine images acquired at low resolution but reconstructed with a deep learning (DL) super-resolution algorithm.

Materials And Methods: Cine cardiovascular magnetic resonance (CMR) datasets (short-axis and 4-chamber views) were prospectively acquired in healthy volunteers and patients at normal (cine: 1.89 × 1.

View Article and Find Full Text PDF

Background: Quantitative cardiovascular magnetic resonance (CMR) first pass perfusion maps are conventionally acquired with 3 short-axis (SAX) views (basal, mid, and apical) in every heartbeat (3SAX/1RR). Thus, a significant part of the left ventricle (LV) myocardium, including the apex, is not covered. The aims of this study were 1) to investigate if perfusion maps acquired with 3 short-axis views sampled every other RR-interval (2RR) yield comparable quantitative measures of myocardial perfusion (MP) as 1RR and 2) to assess if acquiring 3 additional perfusion views (i.

View Article and Find Full Text PDF

Purpose: This study aimed to develop and validate a deep learning-based method that detects inter-breath-hold motion from an estimated cardiac long axis image reconstructed from a stack of short axis cardiac cine images.

Methods: Cardiac cine magnetic resonance image data from all short axis slices and 2-/3-/4-chamber long axis slices were considered for the study. Data from 740 subjects were used for model development, and data from 491 subjects were used for testing.

View Article and Find Full Text PDF

Background: Repaired tetralogy of Fallot (RTOF) patients will develop right ventricular (RV) dysfunction from chronic pulmonary regurgitation (PR). Cardiac magnetic resonance sequences such as four-dimensional flow can demonstrate altered vorticity and flow energy loss (FEL); however, they are not as available as conventional echocardiography (echo). The study determined whether a novel, vendor-independent Doppler velocity reconstruction (DoVeR) could measure RV intracardiac flow in conventional echo of RTOF patients.

View Article and Find Full Text PDF

Echocardiography Provides a Reliable Estimate of Total Cardiac Volume for Pediatric Heart Transplantation.

J Am Soc Echocardiogr

February 2023

Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio; Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio.

Background: Donor-to-recipient size matching for heart transplantation typically involves comparing donor and recipient body weight; however, weight is not linearly related to cardiac size. Attention has shifted toward the use of computed tomography- (CT-) derived total cardiac volume (TCV), that is, CT-TCV, to compare donor and recipient heart organ size. At this time, TCV size matching is near impossible for most centers due to logistical limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!