Autologous fibrin-based tissue-engineered heart valves have demonstrated excellent potential as patient-derived valve replacements. The present pilot study aims to evaluate the structure and mechanical durability of fibrin-based heart valves after implantation in a large-animal model (sheep). Tissue-engineered heart valves were molded using a fibrin scaffold and autologous arterial-derived cells before 28 days of mechanical conditioning. Conditioned valves were subsequently implanted in the pulmonary trunk of the same animals from which the cells were harvested. After 3 months in vivo, explanted valve conduits (n = 4) had remained intact and exhibited native tissue consistency, although leaflets demonstrated insufficiency because of tissue contraction. Routine histology showed remarkable tissue development and cell distribution, along with functional blood vessel ingrowth. A confluent monolayer of endothelial cells was present on the valve surface, as evidenced by scanning electron microscopy and positive von Willebrand factor staining. Immunohistochemistry and extracellular matrix (ECM) assay demonstrated complete resorption of the fibrin scaffold and replacement with ECM proteins. Transmission electron microscopy revealed mature collagen formation and viable, active resident tissue cells. The preliminary findings of implanted fibrin-based tissue-engineered heart valves are encouraging, with excellent tissue remodeling and structural durability after 3 months in vivo. The results from this pilot study highlight the potential for construction of completely "autologous" customized tissue-engineered heart valves based on a patient-derived fibrin scaffold.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/ten.TEA.2009.0018 | DOI Listing |
JACC Case Rep
January 2025
Interventional Cardiology Section, Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA.
Aneurysms of the interventricular membranous septum are a rare anatomical feature that can be detected incidentally on computed tomography or echocardiography. Such aneurysms can pose challenges in the treatment of patients with aortic valve stenosis. A case series of 2 patients with membranous septal aneurysms treated successfully with current-generation balloon-expandable and self-expanding transcatheter heart valves is presented here.
View Article and Find Full Text PDFVet Radiol Ultrasound
January 2025
AniCura Istituto Veterinario Novara, Monticello, Italy.
With the advancement in imaging technology, ECG-gated cardiac multidetector computed tomography (MDCT) has emerged as a tool for the anatomic evaluation of the pulmonary valve and right ventricular outflow tract (RVOT) in human medicine. Currently, the evaluation of the pulmonary valve relies primarily on echocardiographic examination. However, the bi-dimensional nature of this technique and the location/orientation of the pulmonary valve in the thoracic cavity can pose challenges.
View Article and Find Full Text PDFJACC Clin Electrophysiol
January 2025
Section of Cardiac Pacing and Electrophysiology, Division of Cardiology, Cleveland Clinic, Cleveland, Ohio, USA.
Background: In patients with mechanical aortic and mitral valves requiring catheter ablation of ventricular tachycardia (VT), a technique for access from the right atrium (RA) to the left ventricle (LV) via puncture of the inferoseptal process of the LV was previously described in a single-center series.
Objectives: This study sought to report the multicenter experience of VT ablation using this novel LV access approach.
Methods: We assembled a multicenter registry of patients with double mechanical valves who underwent VT ablation with RA-to-LV access.
J Arrhythm
February 2025
Division of Cardiology, Department of Medicine, Heart Rhythm Center Taipei Veterans General Hospital Taipei Taiwan.
With the cases of mechanical valves, especially double mitral and aortic valves, ablation at the left ventricle is very challenging. This case report used equipments that are readily available in the Electrophysiology laboratory, which can make the access feasible.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Cardiology Bichat, AP-HP, Paris, France.
Objectives: Transcatheter edge-to-edge repair (TEER) is an alternative for patients with severe degenerative mitral regurgitation (MR). The objective of this study was to compare the outcomes of surgery and TEER in older patients with degenerative MR patients using real life data.
Methods: Consecutives older patients (≥ 65 years-old), with severe symptomatic, degenerative MR requiring surgery or TEER between 2013 and 2023 were included.