A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of irradiation on the blood dynamics. | LitMetric

The effects of irradiation on the blood dynamics.

Clin Hemorheol Microcirc

Department of Radiation Oncology, Inönü University Faculty of Medicine, Malatya, Turkey.

Published: May 2009

Aim: The present study evaluates the effects of irradiation on the blood dynamics.

Materials And Methods: Thirty-six volunteers providing written consent participated. A blood sample was transferred into three tubes containing CPDA-1 solution while another blood sample was transferred into three tubes containing heparin. Each tube containing CPDA-1 solution was paired with another tube containing heparin. The first pair was not irradiated, not stored and analyzed immediately (Group 1). The second pair was not irradiated, stored and analyzed at seven days (Group 2). The third pair was irradiated, stored and analyzed at seven days (Group 3). The blood count was performed and the blood viscosity was determined.

Results: The mean hemoglobin contents were 126 g/l for Group 1, 128 g/l for Group 2 and 129 g/l for Group 3. For the mean hemoglobin contents, the difference between Group 1 and Group 3 (P<0.001) and Group 2 and Group 3 (P=0.01) were significant. The mean red blood cell volumes were 81.8 fl for Group 1, 82.1 fl for Group 2 and 82.3 fl for Group 3. For the mean red blood cell volumes, the difference between Group 1 and Group 2 (P=0.003) and Group 1 and Group 3 (P=0.006) were significant. The mean blood viscosities were 2.2 mPa s for Group 1, 2.8 mPa s for Group 2 and 3.2 mPa s for Group 3. For the mean blood viscosities, the difference between Group 1 and Group 2 (P<0.001), Group 1 and Group 3 (P<0.001) and Group 2 and Group 3 (P=0.004) were significant.

Conclusion: The present study indicates that the recommended doses of irradiation for the blood products to be used in attempt to prevent the transfusion associated graft versus host disease leads to marked alterations in the blood dynamics and might decrease the viability of the red blood cells following transfusion.

Download full-text PDF

Source
http://dx.doi.org/10.3233/CH-2009-1177DOI Listing

Publication Analysis

Top Keywords

pair irradiated
12
irradiated stored
12
stored analyzed
12
g/l group
12
effects irradiation
8
irradiation blood
8
blood sample
8
sample transferred
8
transferred three
8
three tubes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!