The calibration of parallel-plate electron ionization chambers at NPL for use with the IPEM 2003 code of practice: summary data.

Phys Med Biol

Radiation Dosimetry Group, National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK.

Published: April 2009

The most recent electron dosimetry code of practice for radiotherapy written by the Institute of Physics and Engineering in Medicine was published in 2003 and is based on the NPL electron absorbed dose to water calibration service. NPL has calibrated many Scanditronix type NACP-02 and PTW Roos type 34001 parallel plate ionization chambers in terms of absorbed dose to water, for use with the code of practice. The results of the calibrations of these chamber types summarized here include the absorbed dose to water sensitivity, where the mean calibration factor standard deviations are 5.8% for NACP-02 chambers and 1.1% for PTW Roos chambers. The correction for the polarity effect is shown to be small (less than 0.2% for all beam qualities) but with a discernible beam quality dependence. The correction for recombination is shown to be consistent and reproducible, and an analysis of these results suggests that the plate separation of the NACP-02 chambers is more variable from chamber to chamber than with the PTW Roos chambers. The calibration of these chambers is shown to be repeatable within +/-0.2% over 2-3 years. It is also shown that check source measurements can be repeated within +/-0.3% over several years. The results justify the use of NACP-02 and PTW 34001 chambers as secondary standards, but also indicate that the PTW 34001 chambers show less variation from chamber to chamber.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/54/8/N01DOI Listing

Publication Analysis

Top Keywords

code practice
12
absorbed dose
12
dose water
12
ptw roos
12
chambers
9
ionization chambers
8
nacp-02 ptw
8
nacp-02 chambers
8
roos chambers
8
chamber chamber
8

Similar Publications

Ethics Committees' Practices in Healthcare, Banking and Research: Key Requirements for Their Functionality.

J Eval Clin Pract

February 2025

Institute of the History of Medicine and Ethics in Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany.

Rationale: To meet concerns about ethical and unethical behavior in their work environments and workplaces, organizations began establishing ethics programs that contain ethics committees (ECs). There is now a tradition and diverse use of ECs for ethical decision-making in many different organizational settings. In addition, ECs have been subject to many publications in books and articles in the scientific literature.

View Article and Find Full Text PDF

MITIGATING OVER-SATURATED FLUORESCENCE IMAGES THROUGH A SEMI-SUPERVISED GENERATIVE ADVERSARIAL NETWORK.

Proc IEEE Int Symp Biomed Imaging

May 2024

Department of Electrical and Computer Engineering, Nashville, TN, USA.

Multiplex immunofluorescence (MxIF) imaging is a critical tool in biomedical research, offering detailed insights into cell composition and spatial context. As an example, DAPI staining identifies cell nuclei, while CD20 staining helps segment cell membranes in MxIF. However, a persistent challenge in MxIF is saturation artifacts, which hinder single-cell level analysis in areas with over-saturated pixels.

View Article and Find Full Text PDF

Introduction According to the World Health Organization (WHO), cardiovascular diseases are the leading cause of death globally, accounting for approximately 17 million deaths annually, with sudden cardiac arrest (SCA) as a significant contributor to this alarming statistic. SCA, the abrupt loss of heart function, is a critical medical emergency that requires early recognition and immediate cardiopulmonary resuscitation (CPR) for the effective resuscitation of victims. Various studies have shown a low level of knowledge regarding CPR in the community.

View Article and Find Full Text PDF

Technical considerations and review of urinary microRNAs as biomarkers for chronic kidney disease in dogs and cats.

Vet Clin Pathol

January 2025

Department of Veterinary Pathobiology, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas, USA.

MicroRNAs (miRNAs or miRs) are small, non-coding RNAs that play a crucial role in gene regulation, making them potential biomarkers for various diseases. In the field of veterinary medicine, there is a growing interest in exploring the diagnostic and therapeutic potential of miRNAs in kidney diseases affecting dogs and cats. This review focuses on the use of urinary miRNAs as biomarkers for chronic kidney disease (CKD) in these companion animals.

View Article and Find Full Text PDF

Medical image annotation is scarce and costly. Few-shot segmentation has been widely used in medical image from only a few annotated examples. However, its research on lesion segmentation for lung diseases is still limited, especially for pulmonary aspergillosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!