A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potential impact of adjusting the threshold of the quantitative D-dimer based on pretest probability of acute pulmonary embolism. | LitMetric

Objectives: The utility of D-dimer testing for suspected pulmonary embolism (PE) can be limited by test specificity. The authors tested if the threshold of the quantitative D-dimer can be varied according to pretest probability (PTP) of PE to increase specificity while maintaining a negative predictive value (NPV) of >99%.

Methods: This was a prospective, observational multicenter study of emergency department (ED) patients in the United States. Eligible patients had a diagnostic study ordered to evaluate possible PE. PTP was determined by the clinician's unstructured estimate and the Wells score. Five different D-dimer assays were used. D-dimer test performance was measured using 1) standard thresholds and 2) variable threshold values: twice (for low PTP patients), equal (intermediate PTP patients), or half (high PTP patients) of standard threshold. Venous thromboembolism (VTE) within 45 days required positive imaging plus decision to treat.

Results: The authors enrolled 7,940 patients tested for PE, and clinicians ordered a quantitative D-dimer for 4,357 (55%) patients who had PTPs distributed as follows: low (74%), moderate (21%), or high (4%). At standard cutoffs, across all PTP strata, quantitative D-dimer testing had a test sensitivity of 94% (95% confidence interval [CI] = 91% to 97%), specificity of 58% (95% CI = 56% to 60%), and NPV of 99.5% (95% CI = 99.1% to 99.7%). If variable cutoffs had been used the overall sensitivity would have been 88% (95% CI = 83% to 92%), specificity 75% (95% CI = 74% to 76%), and NPV 99.1% (95% CI = 98.7% to 99.4%).

Conclusions: This large multicenter observational sample demonstrates that emergency medicine clinicians currently order a D-dimer in the majority of patients tested for PE, including a large proportion with intermediate PTP and high PTP. Varying the D-dimer's cutoff according to PTP can increase specificity with no measurable decrease in NPV.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1553-2712.2009.00368.xDOI Listing

Publication Analysis

Top Keywords

quantitative d-dimer
16
ptp patients
12
ptp
9
threshold quantitative
8
d-dimer
8
pretest probability
8
pulmonary embolism
8
d-dimer testing
8
ptp increase
8
increase specificity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!