We wish to determine the urinary trans,trans-muconic acid reference values in the Tunisian general population, and evaluate the impact of several factors (age, gender, tobacco...) on these reference values. Urine samples were collected from 182 healthy Tunisian subjects who had not been occupationally exposed to benzene. This determination was performed by solid phase extraction sampling technique together with high performance liquid chromatography-photodiode array detector. Trans,trans-muconic values ranged from 0.003 to 0.618 mg/g creatinine, the 95% reference interval was: 0.004-0.36, and the 90% confidence interval of the upper reference limit was: 0.24-0.62 mg/g creatinine. Urinary trans,trans-muconic levels were significantly higher among smokers. Significant differences were also observed for the < 20 and the > or = 40 age groups. As a result urinary trans,trans-muconic background levels allow the biomonitoring of workers occupationally exposed to benzene at levels as low as 0.5 ppm. Age and tobacco, but not gender may affect the trans,trans-muconic reference values.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1684/abc.2009.0310 | DOI Listing |
PLoS One
January 2025
School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, P. R. China.
Purpose: To evaluate the corneal biomechanical properties of phacoemulsification in the treatment of cataract patients.
Methods: Pertinent studies were searched in PubMed, EMBASE, Web of Science and clinicaltrials.gov.
J Magn Reson Imaging
January 2025
Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
Background: MRI offers quantification of proton density fat fraction (PDFF) and tissue characteristics with T1 mapping. The influence of age, sex, and the potential confounding effects of fat on T1 values in skeletal muscle in healthy adults are insufficiently known.
Purpose: To determine the accuracy and repeatability of a saturation-recovery chemical-shift encoded multiparametric approach (SR-CSE) for quantification of T1 and muscle fat content, and establish normative values (age, sex) from a healthy cohort.
Scand J Clin Lab Invest
January 2025
Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
Background: Direct oral anticoagulants (DOACs) can interfere with coagulation analyses, causing erroneous results such as false-positive lupus anticoagulant and false-normal antithrombin, threatening patient safety when overlooked. A test using a prothrombin time quotient method to detect DOAC presence in plasma samples is now commercially available, the MRX PT DOAC, with the result expressed as Clot Time Ratio (CTR).
Objectives: Evaluate the ability of MRX PT DOAC to identify interfering apixaban or rivaroxaban concentrations, identify non-interfering or interfering patient samples, and detect whether a patient is on DOAC treatment.
Stat Med
February 2025
Clinical Epidemiology Unit, Complexo Hospitalario de Santiago de Compostela, Galicia, Spain.
Correlated clinical measurements are routinely interpreted via comparisons with univariate reference intervals examined side by side. Multivariate reference regions (MVRs), i.e.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Department of Neurosurgery and Neurooncology, Medical University of Lodz, Barlicki University Hospital, Lodz, Poland.
Background: The internal venous system of the brain is a crucial anatomical landmark during accesses to the third ventricle through the foramen of Monro. Many classifications based on radiological assessment of the system have been developed, but they tend to be descriptive and do not highlight favorable anatomical variants. The aim of our study was to create a system based on morphometric measurements to facilitate preoperative decision-making regarding access to third ventricle tumors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!