A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a multi-layer ionization chamber for heavy-ion radiotherapy. | LitMetric

A multi-layer ionization chamber (MLIC) which consists of a stack of parallel plate-type ionization chambers in which the parallel configuration is in the depth direction was developed at the National Institute of Radiological Science (NIRS) and has been used as a field dosimeter for MU calibration since 2002. Although the MLIC can measure depth dose distributions at one time, a correction is needed to obtain an accurate dose at the center of the spread-out Bragg peak (SOBP) in a water phantom. We attributed the observed difference between the correct dose at the center of the SOBP and the measured dose to the lack of water equivalence of the MLIC. In order to overcome this problem, a new MLIC was developed. It consists of polymethyl-methacrylate (PMMA) plates and graphite electrodes instead of flame retardant type 4 (FR4) and copper electrodes. The calibration coefficients of the MLICs were obtained by 160 MeV proton beam irradiation. For carbon-ion beams, the PMMA type MLIC has the capability to measure depth dose distributions in the water phantom with less than 2% error, including the fragment tail region.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/54/7/N04DOI Listing

Publication Analysis

Top Keywords

multi-layer ionization
8
ionization chamber
8
measure depth
8
depth dose
8
dose distributions
8
dose center
8
water phantom
8
mlic
5
dose
5
development multi-layer
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!