Protrusion of the ceramic head through the acetabular shell in total hip replacement.

Orthopedics

Orthopedic Department, Naoussa General Hospital, 16 Omogenon Amerikis, str, 42200 Kalambaka, Thessaly, Greece.

Published: August 2008

Total hip replacement (THR) is one of the most successful elective operations currently being performed. However, increased implant wear in the femoral head-acetabulum articulation has been found to limit the long-term survivorship of the procedure. Clinical complications of this wear process include mechanical failure of the polyethylene insert as well as a biologic foreign-body response to wear debris. Factors that have been implicated in the pathogenesis of this phenomenon include implant design and positioning, patient age, and time from the operation. Pain and sound originating from the joint are among the most common clinical manifestations. Radiographic signs present in the form of progressive radiolucent zones or an eccentrically displaced femoral head. The true extent of bone damage usually is greater than that appreciated originally. A high index of suspicion is essential for an early and successful surgical intervention. We report a rare case of a 72-year-old woman who presented with excessive wear of both the acetabular polyethylene socket and metal backing 3 years after the initial cementless THR. This resulted in protrusion of the femoral head through both the polyethylene cup and the acetabular shell, and subsequent subluxation of the femoral head. Marked periacetabular osteolysis and loosening had developed progressively. No definite signs of infection were identified, either by bone scintigraphy, preoperatively, or by repeated cultures of the excised tissues. The THR was revised, in a 2-stage operation, using bone autografts and a cemented acetabular socket, with a good postoperative outcome.

Download full-text PDF

Source

Publication Analysis

Top Keywords

femoral head
12
acetabular shell
8
total hip
8
hip replacement
8
protrusion ceramic
4
head
4
ceramic head
4
acetabular
4
head acetabular
4
shell total
4

Similar Publications

Background: The endoplasmic reticulum stress (ER stress) has been involved in various musculoskeletal disorders including non-traumatic osteonecrosis of femoral head (NT-ONFH).

Objective: The current study aimed to investigate the association of glucose-regulated protein 78 (GRP78) as well as CCAAT/enhancer-binding protein homologous protein (CHOP) expressions in serum and femoral head (FH) tissues with NT-ONFH's severity.

Methods: We enrolled NT-ONFH patients (n = 150) alongside healthy controls (HCs, n = 150).

View Article and Find Full Text PDF

Alcoholic osteonecrosis of the femoral head (AIONFH) is caused by long-term heavy drinking, which leads to abnormal alcohol and lipid metabolism, resulting in femoral head tissue damage, and then pathological necrosis of femoral head tissue. If not treated in time in clinical practice, it will seriously affect the quality of life of patients and even require hip replacement to treat alcoholic femoral head necrosis. This study will confirm whether M2 macrophage exosome (M2-Exo) miR-122 mediates alcohol-induced BMSCs osteogenic differentiation, ultimately leading to the inhibition of femoral head necrosis.

View Article and Find Full Text PDF

Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).

Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.

View Article and Find Full Text PDF

Objective: Spinopelvic sagittal balance ensures efficient posture and minimizes energy expenditure by aligning the spine, pelvis, and lower extremities. Deviations can cause clinical issues like back pain and functional limitations. Key radiographic parameters, including pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), and lumbar lordosis (LL), are essential for evaluating spinal pathologies and planning surgeries.

View Article and Find Full Text PDF

Surveillance of Dual-Mobility Hip Systems: Damage Mode and Clinical Data Analysis.

J Arthroplasty

January 2025

Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:

Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.

Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.

View Article and Find Full Text PDF