Analysis of the fetal ECG (fECG) allows physicians to detect changes in the well-being state of the fetus. But when assessing the fECG through the abdominal signals (ADS), its very low amplitude causes a problem, as the fECG representation in the ADS is buried in a mixture of other signals with stronger energy. Different methods have been proposed in the past to extract the transabdominal fECG for instantaneous fetal heart rate (fHR) computation; four representatives of them are selected for an accurate comparison of their performance in fECG extraction and in fHR estimation. A model for the ADS including all the possible disturbances is developed within this study to generate simulated data as they are required for the quantitative comparison of the algorithms. Their performances and limits considering both the enhancement of the fECG and the ability to preserve fECG morphology are analyzed using the simulated data. The results clearly show that linear methods for maternal ECG removal provide better results with respect to the extraction of the fECG morphology. The algorithms are then tested on real ADS data recorded during labor. Finally, the advantage of considering linear methods for ADS processing is discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1515/BMT.2009.008DOI Listing

Publication Analysis

Top Keywords

low amplitude
8
fetal ecg
8
fecg
8
simulated data
8
fecg morphology
8
linear methods
8
ads
5
comparison evaluation
4
evaluation existing
4
methods
4

Similar Publications

Multifunctional SERS Chip for Biological Application Realized by Double Fano Resonance.

Nanomaterials (Basel)

December 2024

Guangdong Provincial Key Laboratory of Photonics Information Technology, Guangdong University of Technology, Guangzhou 510006, China.

The in situ and label-free detection of molecular information in biological cells has always been a challenging problem due to the weak Raman signal of biological molecules. The use of various resonance nanostructures has significantly advanced Surface-enhanced Raman spectroscopy (SERS) in signal enhancement in recent years. However, biological cells are often immersed in different formulations of culture medium with varying refractive indexes and are highly sensitive to the temperature of the microenvironment.

View Article and Find Full Text PDF

The smaller-incision new-generation implantable miniature telescope (SING IMT) represents an advancement over the previous model, WA-IMT, serving as a unilateral prosthetic device for patients with late-stage age-related macular degeneration (AMD). This study aims to report changes in multifocal electroretinography (mfERG) 6 months post-SING IMT implantation. In this case series, we prospectively evaluated a cohort of phakic patients with late-stage AMD who underwent SING IMT implantation at the Ophthalmology Unit, University of Bari Aldo Moro, Italy.

View Article and Find Full Text PDF

Rheological Properties and Physical Stability of Aqueous Dispersions of Flaxseed Fibers.

Gels

December 2024

Departamento de Ingeniería Química, Escuela Politécnica Superior, Universidad de Sevilla, E41011 Sevilla, Spain.

The main objective of this work is to investigate the influence of shear on the rheological properties and physical stability of aqueous dispersions of flaxseed fiber. The variable to consider will be the homogenization rate in two different rotor-stator homogenizers, Ultraturrax T50 or T25. In order to achieve the proposed objective, small amplitude oscillatory tests, flow curves, and multiple light scattering measurements were carried out.

View Article and Find Full Text PDF

Unraveling EEG correlates of unimanual finger movements: insights from non-repetitive flexion and extension tasks.

J Neuroeng Rehabil

December 2024

Laboratory for Neuro- & Psychophysiology, Department of Neurosciences, KU Leuven, Leuven, Belgium.

Background: The loss of finger control in individuals with neuromuscular disorders significantly impacts their quality of life. Electroencephalography (EEG)-based brain-computer interfaces that actuate neuroprostheses directly via decoded motor intentions can help restore lost finger mobility. However, the extent to which finger movements exhibit distinct and decodable EEG correlates remains unresolved.

View Article and Find Full Text PDF

This work presents air-coupled piezoelectric micromachined ultrasonic transducers (pMUTs) with high sound pressure level (SPL) under low-driving voltages by utilizing sputtered potassium sodium niobate KNaNbO (KNN) films. A prototype single KNN pMUT has been tested to show a resonant frequency at 106.3 kHz under 4 V with outstanding characteristics: (1) a large vibration amplitude of 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!