Background: Knowledge of the benefits of incorporating medical simulation into healthcare curricula is rapidly increasing. Though impeded by the high cost of complicated technology, medical simulation devices offer the ability to provide safe and controlled training environments, exposure to rare clinical scenarios, as well as unlimited training opportunities.

Methods: This report describes a novel, inexpensive method of broadcasting normal and abnormal auscultatory findings to a relatively normal appearing stethoscope for use in training of healthcare professionals.

Results: Using wireless transmitter broadcasting to a stethoscope fitted with a receiver apparatus, the student is able to perform a typical medical exam with auscultation of an unlimited variety of clinical sounds from anatomically appropriate sources while being observed from another room.

Conclusions: Implications of this low-cost device include limitless training possibilities worldwide and across disciplines. The simplicity and portability of this device increases potential for use in rapid training of recognition of clinical signs associated with chemical/biological warfare agents, mass casualty incidents and field military applications. This is the first device to simulate clinically relevant sounds in a realistic manner on standardized patients and mannequins. The benefits of such simulation in medical education ultimately serve to increase trainee confidence and consequently, improve patient care and safety.

Download full-text PDF

Source
http://dx.doi.org/10.1080/01421590802516798DOI Listing

Publication Analysis

Top Keywords

medical simulation
8
training
5
ventriloscope 'am
4
'am hearing
4
hearing things?'
4
things?' background
4
background knowledge
4
knowledge benefits
4
benefits incorporating
4
medical
4

Similar Publications

Alzheimer's disease (AD) is associated with cognitive impairments which are linked to a deficit in cholinergic function. The objective of this study was to evaluate the ability of TeMac™ to prevent memory impairment in scopolamine-rats model of Alzheimer's disease and by in silico approaches to identify molecules in TeMac™ inhibiting acetylcholinesterase. The cholinergic cognitive dysfunction was induced by intraperitoneal injection of scopolamine (1 mg/kg daily) in male Wistar rats for seven consecutive days.

View Article and Find Full Text PDF

Purpose: To evaluate whether adult and pediatric trauma center status, as well as the presence of dedicated child protection teams, influences radiology resident performance in detecting non-accidental trauma on the Emergent/Critical Care Imaging Simulation (WIDI SIM) exam.

Materials And Methods: We retrospectively analyzed 639 WIDI SIM exam scores for four pediatric non-accidental trauma cases completed by radiology residents across 33 programs. Residents were stratified by level (R1-R4) and institutional factors, including adult trauma center status, pediatric trauma center status, and child protection team presence.

View Article and Find Full Text PDF

The uncertain ferroptosis-related role of berberine in prostate cancer was explored using network pharmacology methodology. Integration of ferroptosis targets in prostate cancer from the Genecard database and berberine targets from the Traditional Chinese Medicine Systems Pharmacology and SwissTargetPrediction databases revealed 17 common targets. Among these, 10 hub genes, including CCNB1, CDK1, AURKA, AR, CDC42, ICAM1, TYMS, NTRK1, PTGS2, and SCD, were identified.

View Article and Find Full Text PDF

The formation of gastric precancerous-lesions (GPLs) has been identified as a critical step in tumorigenesis, and patients with GPLs have an increased risk of gastric cancer. Magnolol is the primary biphenolic compound in Magnolia officinalis. It possesses various pharmacological properties, such as cardioprotective and neuroprotective properties, and inhibit tumor growth.

View Article and Find Full Text PDF

Photon-Counting CT Effects on Sensitivity for Liver Lesion Detection: A Reader Study Using Virtual Imaging.

Radiology

January 2025

From the Department of Radiology, Duke University Hospital, 2301 Erwin Rd, Box 3808, Durham, NC 27701 (B.W.T., K.R.K., B.C.A., S.P.T., D.E.K., B.H., M.R.B., D.M., E.S., E.A.); Department of Biostatistics and Bioinformatics (N.F., S.M., A.E.) and Department of Medical Physics (W.P.S., E.S., E.A.), Duke University, Durham, NC.

Background Detection of hepatic metastases at CT is a daily task in radiology departments that influences medical and surgical treatment strategies for oncology patients. Purpose To compare simulated photon-counting CT (PCCT) with energy-integrating detector (EID) CT for the detection of small liver lesions. Materials and Methods In this reader study (July to December 2023), a virtual imaging framework was used with 50 anthropomorphic phantoms and 183 generated liver lesions (one to six lesions per phantom, 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!