A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Poly (lactic-co-glycolic acid) as a controlled release delivery device. | LitMetric

Poly (lactic-co-glycolic acid) as a controlled release delivery device.

J Mater Sci Mater Med

Department of Orthopaedic Surgery, National University of Singapore, Kent Ridge, Singapore, Singapore.

Published: August 2009

Poly (lactic-co-glycolic acid) (PLGA) is a biodegradable polymer used to make resorbable sutures, and is also used in other applications in tissue engineering. Being an artificial polymer, its degradation rate can be tailored to suit its application. It can be easily moulded into structures with suitable mechanical strength and degrades into relatively harmless products in the body. Its adjustable degradation rate also makes it a potentially excellent controlled release delivery device. However, the functionalization of PLGA with bioactive molecules usually requires extensive chemical modification. Chemical modification may compromise the mechanical strength of PLGA and inactivate the bioactive molecules. In this paper, a study is done to investigate the coating of an angiogenic factor on unmodified PLGA suture substrates for the differentiation of human mesenchymal stem cells (hMSC) into endothelial cells (EC). The results show that the method used to anchor vascular endothelial growth factor (VEGF) onto the PLGA surface can enable the gradual release of VEGF from the substrate into solution to induce the differentiation of hMSCs into ECs. Thus, this method can potentially be used to coat PLGA materials like sutures, meshes and scaffolds, rendering them functional as effective controlled release delivery devices for a wide range of bioactive molecules.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-009-3727-zDOI Listing

Publication Analysis

Top Keywords

controlled release
12
release delivery
12
bioactive molecules
12
poly lactic-co-glycolic
8
lactic-co-glycolic acid
8
delivery device
8
degradation rate
8
mechanical strength
8
chemical modification
8
plga
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!