Reduction of posterior capsule opacification (PCO) after cataract surgery has been achieved since the general acceptance of posterior chamber intraocular lens implantation 30 years ago. Attention to surgical technique on the one hand and changes in lens design and materials on the other have synergistically reduced the incidence of PCO to less than 5% at 5 years. But lens epithelial cells still proliferate and pharmacological prevention has been largely unsuccessful so far. Any agent must be toxic to these lens epithelial cells without being toxic to the corneal endothelium. This review looks at many substances that have been tried and a few that have been partly successful without yet entering clinical practice. Possibilities for future clinical research are canvassed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1442-9071.2009.01921.x | DOI Listing |
Retina
October 2024
Department of Ophthalmology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.
Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.
Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.
Clin Kidney J
January 2025
Healthy Aging Research Center, Chang Gung University, Taoyuan City, Taiwan.
Background: Damage to brain white matter often occurs in individuals with chronic kidney disease, which might be related to their cognitive decline. This study aims to investigate tract-specific white matter damage in patients with end-stage kidney disease by using fixel-based analysis.
Methods: Images of 31 end-stage kidney disease patients and 16 normal controls (aged: 61.
J Ophthalmol
December 2024
Department of Optics & Optometry & Vision Sciences, University of Valencia, Valencia, Spain.
This study aims to analyze the prevalence and severity of posterior capsule opacification (PCO) and glistening in a new hydrophobic biaspheric monofocal intraocular lens (IOLs) 24 months after implantation. By means of a ambispective, observational, case-control design, a total of 297 eyes from 200 cataract surgery patients were included in the study (118 females and 82 males; mean age: 72.31 ± 9.
View Article and Find Full Text PDFJOR Spine
March 2025
Department of Orthopedics, Luzhou Key Laboratory of Orthopedic Disorders, The Affiliated Traditional Chinese Medicine Hospital Southwest Medical University Luzhou Sichuan Province People's Republic of China.
Background: There are differences in the extent of excision of articular processes, spinal processes and posterior ligamentum complexes (PLC) for posterior approach lumbar interbody fusion. Given that the biomechanical significance of these structures has been verified and that deterioration of the biomechanical environment is the main trigger for complications in both fused and adjacent motion segments, changes in decompression ranges may affect the potential risk of adjacent segmental disease (ASD) biomechanically; however, this topic has yet to be identified.
Methods: Posterior lumbar interbody fusion (PLIF) with different decompression strategies was simulated in a well-validated lumbosacral model.
Arthrosc Tech
December 2024
Division of Sports Medicine, Department of Orthopaedic Surgery, Virginia Commonwealth University Health Systems, Richmond, Virginia, U.S.A.
Remplissage is a procedure that decreases the rate of recurrent instability after arthroscopic stabilization in patients with an engaging Hill-Sachs lesion. This technique involves capsulotenodesis of the infraspinatus tendon and posterior capsule into the Hill-Sachs lesion using 2 knotless anchors with suture passage through the infraspinatus tendon guided by a percutaneous needle. Previously described techniques use knots or anchor placement through the infraspinatus, which can be challenging to control and irreversible if tendon penetration occurs in an undesirable location.