A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Revisional laparoscopic parastomal hernia repair. | LitMetric

Revisional laparoscopic parastomal hernia repair.

JSLS

Department of Biosurgery and Surgical Technology, Imperial College London, St Mary's Hospital, London United Kingdom.

Published: March 2009

Background: We herein report a laparoscopically performed re-do operation on a patient who had previously undergone a laparoscopic parastomal hernia repair.

Case Report: We describe the case of a 71-year-old patient who presented within 3 months of her primary laparoscopic parastomal hernia repair with recurrence. On relaparoscopy, dense adhesions to the mesh were found, and the mesh had migrated into the hernia sac. This had allowed loops of small bowel to herniate into the sac. The initial part of the procedure involved the lysis of adhesions. A piece of Gore-Tex DualMesh with a central keyhole and a radial slit was cut so that it could provide at least 3 cm to 5 cm of overlap of the fascial defect. The tails of the mesh were wrapped around the bowel, and the mesh was secured to the margins of the hernia with circumferential metal tacking and 4 transfascial sutures. The patient remains in satisfactory condition and no recurrence or any surgery-related problem has been observed during 8 months of follow-up.

Conclusion: Revisional laparoscopic repair of parastomal hernias seems feasible and has been shown to be safe and effective in this case. The success of this approach depends on longer follow-up reports and standardization of the technical elements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015990PMC

Publication Analysis

Top Keywords

laparoscopic parastomal
12
parastomal hernia
12
revisional laparoscopic
8
hernia repair
8
hernia
5
parastomal
4
repair background
4
background report
4
report laparoscopically
4
laparoscopically performed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!