The microphone in real ear (MIRE) protocol allows the assessment of hearing protector's (HPD) attenuation in situ by measuring the difference between the sound pressure outside and inside the ear canal behind the HPD. Custom-made earplugs have been designed with an inner bore to insert the MIRE probe containing two microphones, the reference microphone measuring the sound pressure outside and the measurement microphone registering the sound pressure behind the HPD. Previous research on a head and torso simulator reveals a distinct difference, henceforth called transfer function, between the sound pressure at the MIRE measurement microphone and the sound pressure of interest at the eardrum. In the current study, similar measurements are carried out on humans with an extra microphone to measure the sound pressure at the eardrum. The resulting transfer functions confirm the global frequency dependency found earlier, but also show substantial variability between the ears with respect to the exact frequency and amplitude of the transfer functions' extrema. In addition, finite-difference time-domain numerical models of an ear canal with earplug are developed for each individual ear by including its specific geometrical parameters. This approach leads to a good resemblance between the simulations and their corresponding measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.3075603 | DOI Listing |
J Morphol
January 2025
Department of Zoology, Denver Museum of Nature & Science, Denver, Colorado, USA.
The barn owl is a common research subject in auditory science due to its exceptional capacity for high frequency hearing and superb sound source localization capabilities. Despite longstanding interest in the auditory performance of barn owls, the function of its middle ear has attracted remarkably little attention. Here, we report the middle ear transfer function measured by laser Doppler vibrometry and direct measurements of inner ear pressures.
View Article and Find Full Text PDFJ Environ Manage
January 2025
Department of Epidemiology and Statistics, School of Public Health, Guangdong Pharmaceutical University, Guangzhou, China. Electronic address:
Background: Environmental noise seriously affects people's health and life quality, but there is a scarcity of noise exposure data in metropolitan cities and at nighttime, especially in developing countries.
Objective: This study aimed to assess the environmental noise level by land use regression (LUR) models and create daytime and nighttime noise maps with high-resolution of Guangzhou municipality.
Methods: A total of 100 monitoring sites were randomly selected according to population density.
J Chem Phys
January 2025
Key Laboratory of Efficient Low-carbon Energy Conversion and Utilization of Jiangsu Provincial Higher Education Institutions, School of Physical Science and Technology, Suzhou University of Science and Technology, Suzhou 215009, China.
Despite the conventional view of liquid aluminum (l-Al) as a simple metal governed by the free-electron model, it exhibits unique bonding characteristics. This study uncovers a gradual transition from free electron to electride behavior in l-Al at high pressure and temperature, forming a type of two-component liquid where atomic and electride states coexist. The proportion of electride increases with pressure and temperature until reaching saturation, leading to notable changes in the pair-correlation function and coordination number of l-Al at saturation pressure.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Key Laboratory of Optoelectronic Technology & Systems of Ministry of Education, International R&D Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing, 400044, China.
Sound signals not only serve as the primary communication medium but also find application in fields such as medical diagnosis and fault detection. With public healthcare resources increasingly under pressure, and challenges faced by disabled individuals on a daily basis, solutions that facilitate low-cost private healthcare hold considerable promise. Acoustic methods have been widely studied because of their lower technical complexity compared to other medical solutions, as well as the high safety threshold of the human body to acoustic energy.
View Article and Find Full Text PDFBMC Health Serv Res
January 2025
Center of Implementing Nursing Care Innovations Freiburg, Nursing Direction, Medical Center - University of Freiburg, Freiburg, Germany.
Background: The noise levels in intensive care units usually exceed the recommended limits in (inter)national recommendations. Such noise levels can affect both the recovery of intensive care patients and the performance of staff. The aim of this study was to reduce ward-based noise levels in three intensive care units (anesthesiological, neurological, and neonatological).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!