Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1200/JCO.2008.21.3447 | DOI Listing |
Anal Chem
January 2025
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha 410082, China.
To facilitate on-site detection by nonspecialists, there is a demand for the development of portable "sample-to-answer" devices capable of executing all procedures in an automated or easy-to-operate manner. Here, we developed an automated detection device that integrated a magnetofluidic manipulation system and a signal acquisition system. Both systems were controllable via a smartphone.
View Article and Find Full Text PDFJ Mol Model
January 2025
State Key Laboratory of Polyolefins and Catalysis, Shanghai, 200062, People's Republic of China.
Context: This study aims to reveal the reaction mechanisms of H and O on the NiO(100) and Ce-doped NiO(100) surfaces using the density functional theory (DFT) combined with the on-site Coulomb correction (DFT + U) method. It was found that H and O react favorably on the reduced surfaces of both materials. However, after the oxygen vacancy is filled, the activation energy for the reaction between H₂ and lattice oxygen increases.
View Article and Find Full Text PDFForensic Sci Med Pathol
January 2025
School of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan.
Matrix-assisted laser Desorption/Ionization Mass Spectrometry Imaging (MALDI MSI) is an analytical technique used for the spatial mapping of drugs, explosives, and organic samples, making it a game-changer in Forensic examination. It detects a wide range of biomolecules in their native state without specific tags, antibodies, labels, and dyes. This review aims to highlight the advancement of MALDI-MSI over time and its impact on Forensic Science due to high-resolution molecular imaging.
View Article and Find Full Text PDFJACC Adv
January 2025
Department of Cardiology, University Heart Centre, University Hospital Zürich, Zürich, Switzerland.
Background: Patients in many underserved geographies lack access to invasive coronary angiography (ICA).
Objectives: This preclinical study explored the feasibility of telerobotic ICA between separate continents.
Methods: Using a novel robotic system, attempts were made to navigate a magnetic guidewire and diagnostic catheter from the aortic arch into a target coronary artery ostium in a fluid-filled cardiac model.
Radiol Adv
October 2024
Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).
Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!