Reproducibility of regional pulse wave velocity in healthy subjects.

Korean J Intern Med

Department of Medical Equipment Information, Vision College of Jeonju, Jeonju, Korea.

Published: March 2009

Background/aims: Despite the clinical importance and widespread use of pulse wave velocity (PWV), there are no standards for pulse sensors or for system requirements to ensure accurate pulse wave measurement. We assessed the reproducibility of PWV values using a newly developed PWV measurement system.

Methods: The system used in this study was the PP-1000, which simultaneously provides regional PWV values from arteries at four different sites (carotid, femoral, radial, and dorsalis pedis). Seventeen healthy male subjects without any cardiovascular disease participated in this study. Two observers performed two consecutive measurements in the same subject in random order. To evaluate the reproducibility of the system, two sets of analyses (within-observer and between-observer) were performed.

Results: The means+/-SD of PWV for the aorta, arm, and leg were 7.0+/-1.48, 8.43+/-1.14, and 8.09+/-0.98 m/s as measured by observer A and 6.76+/-1.00, 7.97+/-0.80, and 7.97+/-0.72 m/s by observer B, respectively. Betweenobserver differences for the aorta, arm, and leg were 0.14+/-0.62, 0.18+/-0.84, and 0.07+/-0.86 m/s, respectively, and the correlation coefficients were high, especially for aortic PWV (r=0.93). All the measurements showed significant correlation coefficients, ranging from 0.94 to 0.99.

Conclusions: The PWV measurement system used in this study provides accurate analysis results with high reproducibility. It is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2687650PMC
http://dx.doi.org/10.3904/kjim.2009.24.1.19DOI Listing

Publication Analysis

Top Keywords

pulse wave
12
wave velocity
8
pwv values
8
pwv measurement
8
system study
8
aorta arm
8
arm leg
8
correlation coefficients
8
pwv
7
pulse
5

Similar Publications

HIFU induces reprogramming of the tumor immune microenvironment in a pancreatic cancer mouse model.

Med Mol Morphol

January 2025

Faculty of Advanced Techno-Surgery (FATS), Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku, Tokyo, 162-8666, Japan.

This study evaluates the effects of different high-intensity focused ultrasound irradiation (HIFU) methods on local tumor suppression and systemic antitumor effects, including the abscopal effect, in a mouse model of pancreatic cancer. To ascertain the efficacy of the treatment, pancreatic cancer cells were injected into the thighs of mice and HIFU was applied on one side using continuous waves or trigger pulse waves. Then, tumor volume, tissue changes, and immune marker levels were analyzed.

View Article and Find Full Text PDF

Transient shear wave elastometry using a portable magnetic resonance sensor.

Magn Reson Med

January 2025

MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.

Purpose: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.

View Article and Find Full Text PDF

Attosecond Rescattering of Laser-Assisted Electron-Proton Collision in Coulomb Potential.

J Phys Chem A

January 2025

Department of Chemistry, University of Malaya, 50603 Kuala Lumpur, Malaysia.

This study investigates the motion of an electron in a Coulomb potential driven by an intense linearly polarized XUV laser pulse analyzed using Gordon-Volkov wave functions. The wave function is decomposed into spherical partial waves to model the scattered electron wave packet after the recollision with a proton. This interaction triggers high harmonic generation, producing coherent X-ray pulses with frequencies that are integer multiples of the XUV field.

View Article and Find Full Text PDF

Background: Emerging evidence suggests that spirituality improves patient outcomes, however, this has undergone only limited evaluation in randomized trials. Hypertension is a major cause of cardiovascular morbidity and mortality worldwide.

Objectives: To evaluate whether a spirituality-based intervention, compared to a control group, can reduce blood pressure (BP) and improve endothelial function after 12 weeks in patients with mild or moderate hypertension (HTN).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!