Hyperpolarization-activated cyclic nucleotide-modulated (HCN) channels resemble Shaker K+ channels in structure and function. In both, changes in membrane voltage produce directionally similar movement of positively charged residues in the voltage sensor to alter the pore structure at the intracellular side and gate ion flow. However, HCNs open when hyperpolarized, whereas Shaker opens when depolarized. Thus, electromechanical coupling between the voltage sensor and gate is opposite. A key determinant of this coupling is the intrinsic stability of the pore. In Shaker, an alanine/valine scan of residues across the pore, by single point mutation, showed that most mutations made the channel easier to open and steepened the response of the channel to changes in voltage. Because most mutations likely destabilize protein packing, the Shaker pore is most stable when closed, and the voltage sensor works to open it. In HCN channels, the pore energetics and vector of work by the voltage sensor are unknown. Accordingly, we performed a 22-residue alanine/valine scan of the distal pore of the HCN2 isoform and show that the effects of mutations on channel opening and on the steepness of the response of the channel to voltage are mixed and smaller than those in Shaker. These data imply that the stabilities of the open and closed pore are similar, the voltage sensor must apply force to close the pore, and the interactions between the pore and voltage sensor are weak. Moreover, cAMP binding to the channel heightens the effects of the mutations, indicating stronger interactions between the pore and voltage sensor, and tips the energetic balance toward a more stable open state.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2708862 | PMC |
http://dx.doi.org/10.1074/jbc.M809164200 | DOI Listing |
Nanoscale
January 2025
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, China.
Two-dimensional (2D) organic-inorganic halide perovskites are promising sensitive materials for optoelectronic applications due to their strong light-matter interactions, layered structure, long carrier lifetime and diffusion length. However, a high gate bias is indispensable for perovskite-based phototransistors to optimize detection performances, since ion migration seriously screens the gate electric field and the deposition process introduces intrinsic defects, which induces severe leakages and large power dissipation. In this work, an ultrasensitive phototransistor based on the (PEA)SnI perovskite and the Al:HfO ferroelectric layer is meticulously studied, working without an external gate voltage.
View Article and Find Full Text PDFACS Omega
January 2025
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea.
Numerous studies have focused on graphene owing to its potential as a next-generation electronic material, considering its high conductivity, transparency, superior mechanical stiffness, and flexibility. However, cost-effective mass production of graphene-based electronics based on existing fabrication methods, such as graphene transfer and metal formation, remains a challenge. This study proposes a simple and efficient method for creating electrical contacts with graphene.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
Alan G. MacDiarmid Institute, College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012, PR China. Electronic address:
Water electrolysis represents a green and efficient strategy for hydrogen (H) production. However, the four-electron transfer process involved in its anodic oxygen evolution reaction (OER) half-reaction restricts the H generation rate. Employing hydrazine oxidation reaction (HzOR) as a substitute for OER in H generation can dramatically reduce energy consumption.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Chair of Measurements and Sensor Technology, Technische Universitat Chemnitz, Reichenhainerstrasse 70, Chemnitz, 09111, GERMANY.
Objective: Electrical Impedance Tomography (EIT) is a non-invasive technique used for lung imaging. A significant challenge in EIT is reconstructing images of deeper thoracic regions due to the low sensitivity of boundary voltages to internal conductivity variations. The current injection pattern is decisive as it influences the current path, boundary voltages, and their sensitivity to tissue changes.
View Article and Find Full Text PDFBackground: Few clinical studies of atrial fibrillation (AF) have focused on Asian patients; data are lacking on current mapping and ablation strategies in the Asia Pacific region (APAC).
Objective: The HD Mapping Observational Study (NCT04022954) was designed to characterize electroanatomic mapping (EAM) with market-released high-density mapping (HDM) catheters in subjects with AF in APAC.
Methods: Subjects undergoing HDM and indicated for radiofrequency ablation (RFA) to treat AF were prospectively enrolled in APAC.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!