Rationale And Objectives: The identification of the most suspect enhancing part of a lesion is regarded as a major diagnostic criterion in dynamic magnetic resonance mammography. Computer-aided diagnosis (CAD) software allows the semi-automatic analysis of the kinetic characteristics of complete enhancing lesions, providing additional information about lesion vasculature. The diagnostic value of this information has not yet been quantified.
Materials And Methods: Consecutive patients from routine diagnostic studies (1.5 T, 0.1 mmol gadopentetate dimeglumine, dynamic gradient-echo sequences at 1-minute intervals) were analyzed prospectively using CAD. Dynamic sequences were processed and reduced to a parametric map. Curve types were classified by initial signal increase (not significant, intermediate, and strong) and the delayed time course of signal intensity (continuous, plateau, and washout). Lesion enhancement was measured using CAD. The most suspect curve, the curve-type distribution percentage, and combined dynamic data were compared. Statistical analysis included logistic regression analysis and receiver-operating characteristic analysis.
Results: Fifty-one patients with 46 malignant and 44 benign lesions were enrolled. On receiver-operating characteristic analysis, the most suspect curve showed diagnostic accuracy of 76.7 +/- 5%. In comparison, the curve-type distribution percentage demonstrated accuracy of 80.2 +/- 4.9%. Combined dynamic data had the highest diagnostic accuracy (84.3 +/- 4.2%). These differences did not achieve statistical significance. With appropriate cutoff values, sensitivity and specificity, respectively, were found to be 80.4% and 72.7% for the most suspect curve, 76.1% and 83.6% for the curve-type distribution percentage, and 78.3% and 84.5% for both parameters.
Conclusions: The integration of whole-lesion dynamic data tends to improve specificity. However, no statistical significance backs up this finding.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acra.2008.10.007 | DOI Listing |
Front Cell Infect Microbiol
January 2025
Department of Clinical Laboratory, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Background: Though droplet digital PCR (ddPCR) has emerged as a promising tool for early pathogen detection in bloodstream infections (BSIs), more studies are needed to support its clinical application widely due to different ddPCR platforms with discrepant diagnostic performance. Additionally, there is still a lack of clinical data to reveal the association between pathogen loads detected by ddPCR and corresponding BSIs.
Methods: In this prospective study, 173 patients with suspected BSIs were enrolled.
Mol Clin Oncol
March 2025
Department of Medical Oncology, Zhangzhou Municipal Hospital Affiliated of Fujian Medical University, Zhangzhou, Fujian 363000, P.R. China.
In recent years, selective lateral lymph node dissection (LLND) has been performed more frequently. The present study aimed to explore the clinical characteristics and predictive factors of pathological lateral pelvic lymph node metastasis (LPLNM), which may be helpful for pre-treatment decisions. The present study included 64 patients with rectal cancer and clinically suspected LPLNM who underwent total mesorectal excision (TME) and LLND between February 2019 and April 2024.
View Article and Find Full Text PDFIntroduction: The real-world safety profiles of the demethylating agents Azacitidine and Decitabine remain inadequately characterized despite their widespread clinical use. Both drugs are extensively employed for the treatment of hematologic malignancies such as myelodysplastic syndromes (MDS) and acute myeloid leukemia (AML). This study aims to evaluate their adverse event (AE) profiles by leveraging data from the U.
View Article and Find Full Text PDFPLoS Negl Trop Dis
January 2025
UQ Centre for Clinical Research, Faculty of Health, Medicine, and Behavioural Sciences, The University of Queensland, Brisbane, Queensland, Australia.
Background: Sensitive diagnostic tools that signal lymphatic filariasis (LF) transmission are needed to monitor the progress of LF elimination programs. Anti-filarial antibody (Ab) markers could be more sensitive than antigen (Ag) point-of-care tests for monitoring LF transmission in some settings. This study aimed to investigate the sensitivity of anti-filarial Abs for detecting signals of LF transmission in Samoa by i) investigating the sensitivity and specificity of Ab to identify Ag-positives; ii) estimating the average number needed to test (NNTestav) to identify LF-seropositives (seropositive for Ag and/or any Ab), and iii) compare the efficiency of the different serological indicators by target age group and sampling design.
View Article and Find Full Text PDFArch Gynecol Obstet
January 2025
Department of Radiology, First People's Hospital of Shangqiu, Shangqiu, 476000, China.
Objective: To assess and compare the diagnostic accuracy of radiologist, MR findings, and radiomics-clinical models in the diagnosis of placental implantation disorders.
Methods: Retrospective collection of MR images from patients suspected of having placenta accreta spectrum (PAS) was conducted across three institutions: Institution I (n = 505), Institution II (n = 67), and Institution III (n = 58). Data from Institution I were utilized to form a training set, while data from Institutions II and III served as an external test set.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!