A non-invasive device to objectively measure tibial rotation: verification of the device.

Knee Surg Sports Traumatol Arthrosc

Department of Orthopedic Surgery, Saarland University, Homburg/Saar, Germany.

Published: July 2009

The purpose of this study was the correlation of the results of a new measurement device for tibial rotation (Rotameter) in comparison with the measurements of a knee navigation system as standard method. In a biomechanical laboratory study, all soft tissues were removed from 20 human cadaveric knees leaving only the intact capsule and the bone. Specific tracers were bicortically fixed in the bone in order to measure tibial rotation using a knee navigation system. The knees were fixed to a custom-made inside-boot to rule out undesirable rotation of the reconstruction inside the Rotameter measurement device. Internal and external rotation values were measured at an applied torque of 5, 10 and 15 Nm. The different methods to evaluate tibial rotation were compared using the Pearson correlation coefficient. The correlations were deemed to be reliable if a value of >or=0.80 was achieved. At 5 Nm of applied torque, high correlations for the internal rotation, external rotation and the entire rotational range were found in the Pearson correlation coefficient between the Rotameter testing device in comparison with the knee navigation system as invasive reference method. These results were also confirmed at an applied torque of 10 and 15 Nm. In conclusion, the Rotameter testing device showed high correlations compared with the knee navigation system as an invasive standard method. It might be used as a non-invasive and easy alternative to investigate tibial rotation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-009-0756-6DOI Listing

Publication Analysis

Top Keywords

tibial rotation
20
knee navigation
16
navigation system
16
applied torque
12
rotation
9
measure tibial
8
measurement device
8
standard method
8
external rotation
8
pearson correlation
8

Similar Publications

An alternative fixation for all mild and moderate hallux valgus cases enabling intraoperative readjustment.

J Orthop Surg Res

January 2025

Department of Orthopaedics and Traumatology, Adana City Training and Research Hospital, University of Health Sciences, Adana, Turkey.

Background: The development of a cost-effective and easily applicable fixation method to address all components of hallux valgus (HV) surgery is of great importance to the field. This study aims to assess the clinical efficacy of an  alternative fixation method that combines the advantages aspects of commonly used distal osteotomy techniques and evaluate its level of applicability in the treatment of mild and moderate HV cases.

Methods: The retrospectively designed study was conducted at Adana City Training and Research Hospital, Adana, Türkiye.

View Article and Find Full Text PDF

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Introduction: Aseptic recalcitrant nonunion (ARNU) of the femur and tibia is an entity in which the absence of bony union, misalignment, and limb length discrepancies (LLD) coexist. Currently, the management of these cases lacks consensus. This study aimed to describe the bone union rate and deformity correction outcomes in patients with ARNU of the femur or tibia treated with the Induced Membrane Technique (IMT).

View Article and Find Full Text PDF

Background: Tibiofemoral rotation is an emerging parameter, especially in assessing patellofemoral instability. However, reference values in the literature are inconsistent regarding the used imaging modality and do not consider the effect of knee flexion during image acquisition.

Purpose: To analyze the differences in tibiofemoral rotation measurements between computed tomography (CT) and magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Introduction: As a result of increased incidence of anterior cruciate ligament (ACL) injury in young athletes, there is a rise in the indications surgical ACL reconstruction procedures. The value of anterolateral ligament (ALL) reconstruction emerges as a proposed solution to prevent graft failures and improve stability in this high demanding category of patients. The purpose of this study is to present our experience with a novel hamstring auto-grafting technique, the single antegrade sling graft (SASG), for combined reconstruction of both ACL and ALL using autologous gracilis (GR) and semitendinosus (ST) grafts utilizing a single femoral tunnel and double tibial tunnels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!