A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study. | LitMetric

Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study.

Am J Crit Care

College of Nursing, Department of Statistics and Actuarial Science, Cardiopulmonary Science Program, University of Central Florida, Orlando, FL 32816-2210, USA.

Published: March 2009

Background: Endotracheal tube cuff pressure must be maintained within a narrow therapeutic range to prevent complications. Cuff pressure is measured and adjusted intermittently.

Objectives: To assess the accuracy and feasibility of continuous monitoring of cuff pressure, describe changes in cuff pressure over time, and identify clinical factors that influence cuff pressure.

Methods: In a pilot study, data were collected for a mean of 9.3 hours on 10 patients who were orally intubated and receiving mechanical ventilation. Sixty percent of the patients were white, mean age was 55 years, and mean intubation time was 2.8 days. The initial cuff pressure was adjusted to a minimum of 20 cm H2O. The pilot balloon of the endotracheal tube was connected to a transducer and a pressure monitor. Cuff pressure was recorded every 0.008 seconds during a typical 12-hour shift and was reduced to 1-minute means. Patient care activities and interventions were recorded on a personal digital assistant.

Results: Values obtained with the cufflator-manometer and the transducer were congruent. Only 54% of cuff pressure measurements were within the recommended range of 20 to 30 cm H2O. The cuff pressure was high in 16% of measurements and low in 30%. No statistically significant changes over time were noted. Endotracheal suctioning, coughing, and positioning affected cuff pressure.

Conclusions: Continuous monitoring of cuff pressure is feasible, accurate, and safe. Cuff pressures vary widely among patients.

Download full-text PDF

Source
http://dx.doi.org/10.4037/ajcc2009441DOI Listing

Publication Analysis

Top Keywords

cuff pressure
40
cuff
13
continuous monitoring
12
pressure
11
pilot study
8
endotracheal tube
8
monitoring cuff
8
assessment endotracheal
4
endotracheal cuff
4
pressure continuous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!