(PBC) is not a rare disease worldwide. Most patients are diagnosed at the advanced stage, primarily because there are not yet any valid biomarkers available for early diagnosis. Useful biomarkers are absolutely necessary for early detection of PBC. Fortunately, the use of MALDI-TOF-MS and pattern recognition software has been successful in finding specific markers for the early detection of the disease. To screen for potential protein biomarkers in the serum for diagnosing PBC, MALDI-TOF-MS combined with magnetic beads and pattern recognition software was used to investigate 119 serum samples from 44 patients with PBC, 32 controls with other hepatic disease, and 43 healthy controls. A total of 69 discriminant m/z peaks were identified as being associated with PBC. Of them, the m/z peaks at 3445, 4260, 8133, and 16,290 were used to construct a model for the diagnosis of PBC. This diagnostic model can distinguish PBC from non-PBC controls with a sensitivity of 93.3% and a specificity of 95.1%. In our blind test, it demonstrated good sensitivity and specificity: 92.9% and 82.4%, respectively. These results indicate that useful serum biomarkers for PBC can be discovered by MALDI-TOF-MS combined with the use of magnetic beads and pattern recognition software. The pattern of multiple markers provides a powerful and reliable diagnostic method for PBC with high sensitivity and specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ar.20870DOI Listing

Publication Analysis

Top Keywords

magnetic beads
12
pattern recognition
12
recognition software
12
pbc
9
early detection
8
maldi-tof-ms combined
8
combined magnetic
8
beads pattern
8
m/z peaks
8
sensitivity specificity
8

Similar Publications

Microfluidic Integration of Magnetically Functionalized Microwires for Flow Cytometry Protein Quantification.

Materials (Basel)

January 2025

Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada.

A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are injected inside microfluidic channels and immobilized magnetically on the surface of glass-coated soft magnetic microwires placed along the symmetry axis of these channels. A fluorescent (Cy5) immunomagnetic sandwich ELISA is then performed by sequentially flowing the sample and all necessary reagents in the microfluidic channels.

View Article and Find Full Text PDF

The association between microRNAs and various diseases, especially cancer, has been established in recent years, indicating that miRNAs can potentially serve as biomarkers for these diseases. Determining miRNA concentrations in biological samples is crucial for disease diagnosis. Nevertheless, the stem-loop reverse transcription quantitative PCR method, the gold standard for detecting miRNA, has great challenges in terms of high costs and enzyme limitations when applied to clinical biological samples.

View Article and Find Full Text PDF

Digital fluorescence immunoassay (DFI) based on random dispersion magnetic beads (MBs) is one of the powerful methods for ultrasensitive determination of protein biomarkers. However, in the DFI, improving the limit of detection (LOD) is challenging since the ratio of signal-to-background and the speed of manual counting beads are low. Herein, we developed a deep-learning network (ATTBeadNet) by utilizing a new hybrid attention mechanism within a UNet3+ framework for accurately and fast counting the MBs and proposed a DFI using CdS quantum dots (QDs) with narrow peak and optical stability as reported at first time.

View Article and Find Full Text PDF

(PCV2) is the main and primary causative agent of Postweaning Multisystemic Wasting Syndrome (PMWS). To date, immunoperoxidase monolayer assay (IPMA), indirect immunofluorescent assay (IFA), and enzyme linked immunosorbent assay (ELISA) are the most commonly diagnostic methods for detecting PCV2 antigens. However, these methods require specialized equipment and technical expertise and are suitable for laboratory use only.

View Article and Find Full Text PDF

Microbial contamination is an important factor threatening the safety of Chinese medicine preparations, and microfluidic detection methods have demonstrated excellent advantages in the application of rapid bacterial detection. In our study, a novel optical biosensor was developed for the rapid and sensitive detection of in traditional Chinese medicine on a microfluidic chip. Immune gold@platinum nanocatalysts (Au@PtNCs) were utilized for specific bacterial labeling, while magnetic nano-beads (MNBs) with a novel high-gradient magnetic field were employed for the specific capture of bacteria.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!