Quantitative ultrasound allows noninvasive assessment of cortical bone density. Potential applications include monitoring of fracture healing, rehabilitation, and skeletal diseases. The objectives of this study were to determine the three most accessible portals to obtain speed of sound measurements of the radius and tibia with an Omnisense multisite quantitative ultrasound device and to determine probe-dependent intra- and interoperator variability for speed of sound measurements of the radius and tibia in six healthy hounds. The radius was most accessible at the cranial proximal metaphysis, the cranial middiaphysis, and medial distal metaphysis. Speed of sound measurements were possible at these sites on the radius with acceptable intra- and interoperator variation (1.6-4.6%). Measurements differed significantly when performed with different probes at the cranial proximal radial metaphysis. The tibia was most accessible at the cranial proximal metaphysis, the medial middiaphysis, and medial distal metaphysis. The medial middiaphyseal and mediodistal tibial sites allowed measurements with lowest intra- and interoperator variation (< 3.5%). A smaller probe allowed tibial measurements with lowest interoperator variation. Measurements did not differ significantly at each tibial site when different probes were used. Measurements did not differ significantly between observers when measuring with the same probe at each specific site on radius and tibia. A medium-size probe allowed for most time-efficient measurements and the least number of failed measurements on the radius and tibia. Speed of sound can be consistently measured by different observers on the radius and tibia in healthy hounds.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1740-8261.2008.01498.x | DOI Listing |
Arch Osteoporos
December 2024
Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
Unlabelled: This study examines how power training affects estimated bone strength, revealing that females benefit more than males, especially in the upper limbs (radius). These findings highlight the importance of designing sex-specific exercise programs to enhance bone health. Further research is needed to optimize training duration and address site-specific differences.
View Article and Find Full Text PDFInjury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFAm J Vet Res
December 2024
Department of Small Animal Surgery, ONIRIS Nantes-Atlantic College of Veterinary Medicine, Food Science, and Engineering, Nantes, France.
Objective: To study the morphology of canine and feline femurs and tibias in lateral radiographic projections and assess their compatibility with either a straight or a curved full-length interlocking nail (ILN).
Methods: Lateral projection radiographs of 50 tibias and 50 femurs (10 cats and 40 dogs per bone) were used to measure the minimum and maximum radius of curvature of an ILN compatible with each bone. These radii were defined by cranial and caudal endosteal points at the proximal entry point of the nail, at the isthmus, and at the most distal point of the ILN insertion into the femoral or tibial metaphysis.
Bone
December 2024
Bone and Joint Center, Henry Ford Health, Detroit, MI, USA; Henry Ford Health + Michigan State University Health Sciences, Detroit, MI, USA. Electronic address:
Bone fractures due to osteoporosis are a significant problem. Limited accuracy of standard bone mineral density (BMD) for fracture risk assessment, combined with low adherence to bone health screening precludes identification of those at risk of fracture. Because of the wide availability of digital breast tomosynthesis (DBT) imaging, bone screening using a DBT scanner at the time of breast screening has been proposed.
View Article and Find Full Text PDFEur J Sport Sci
January 2025
Department of Physical Education and Sports, Research Group in Sports Biomechanics (GIBD), Universitat de València, Valencia, Spain.
Sprinting on bends demands biomechanical adjustments compared with straight-line sprinting that results in asymmetrical force production in the lower extremities. This study aimed to assess acceleration impacts in the lower extremity and impact transmission when sprinting on bend versus straight lanes. Eight experienced sprinters (age 16.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!