Background: Myocardial revascularization using a complete heart-lung machine may involve many problems, as do complete off-pump attempts. Thus, it was the aim of this study to evaluate the effects of intermediate on-pump/off-pump myocardial revascularization using the miniaturized Deltastream blood pump, on ischemia and hemolysis, in comparison with standard myocardial revascularization.
Methods: In a group of 8 mini-pigs, combined on-pump/off-pump myocardial revascularization was performed using the Deltastream blood pump as beating-heart support for the on-pump part of the operation (group A). Seven other animals served as controls and underwent standard myocardial revascularization with the same device as integrated pump of a complete heart-lung machine (group B). Blood samples for blood gas metabolism, creatine kinase (CK), troponin I, lactate dehydrogenase (LDH), and hydroxybutyrate dehydrogenase (HBDH) were taken before and after the entire operation.
Results: Comparing the baseline values, the increase of CK was more pronounced in group B than in group A (176.4-/+41.2 to 279.7-/+29 U/L vs. 274-/+142.7 to 288.1-/+118.6 U/L, respectively; p=0.0006). Increase of troponin I was significantly higher in group B than in group A (1-/+0.3 to 2.9-/+1 ng/mL vs. 1.1-/+0.9 to 3-/+3.8 ng/mL, respectively; p=0.002). LDH increase was also more pronounced in group B (231.7-/+54.3 to 299.9-/+39.8 U/L vs. 274.9-/+59.7 to 263.8-/+57.9 U/L, respectively; p=0.01). HBDH values increased significantly in group B after the operation (group A: 215.9-/+34.7 to 200-/+39.2 U/L vs. group B: 195.4-/+41.7 to 274.9-/+51.6 U/L; p=0.02). Hemodynamic measures and LDH values under luxation (group A: 1.9-/+0.6 U/L; B: 3.5-/+1 U/L,p=0.001) were also superior in the study group.
Conclusion: The current set-up might be superior to conventional extracorporeal circulation and thus be an alternative for high-risk candidates to avoid the adverse events of a complete heart-lung machine, when they are scheduled for complete myocardial revascularization.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/039139880903200106 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Gangnam-gu, South Korea.
Background: There is a paucity of data regarding drug-coated balloon (DCB) treatment in the context of left main (LM) true bifurcation lesions.
Aims: The aim of this study was to evaluate the safety and efficacy of DCB-based treatment for unprotected LM true bifurcation lesions.
Methods: A total of 39 patients with LM true bifurcation lesion (Medina: 1,1,1/0,1,1/1,0,1) who were successfully treated with DCB alone or in combination with drug-eluting stent (DES) were retrospectively enrolled into the DCB-based group.
Circ Cardiovasc Interv
January 2025
Department of Cardiology, Radboud University Medical Center, Nijmegen, the Netherlands (R.H.J.A.V., J.-Q.M., N.v.R.).
Background: Despite fractional flow reserve (FFR)-guided deferral of revascularization, recurrent events in patients with diabetes or after myocardial infarction remain common. This study aimed to assess the association between FFR-negative but high-risk nonculprit lesions and clinical outcomes.
Methods: This is a patient-level pooled analysis of the prospective natural-history COMBINE (OCT-FFR) study (Optical Coherence Tomography Morphologic and Fractional Flow Reserve Assessment in Diabetes Mellitus Patients) and PECTUS-obs study (Identification of Risk Factors for Acute Coronary Events by OCT After STEMI and NSTEMI Patients With Residual Non- Flow Limiting Lesions).
Circ Cardiovasc Interv
January 2025
Department of Cardiology, Odense University Hospital, Denmark (K.N.H., J.T., M.N., M.H., J.E.-G., K.T.V., A.J., H.S.H., J.F.L., L.O.J.).
Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.
Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.
Adv Sci (Weinh)
January 2025
Key Laboratory of Cardiovascular and Cerebrovascular Medicine, School of Pharmacy, Nanjing Medical University, 101 Longmian Avenue, Jiangning District, Nanjing, 211166, P. R. China.
Myocardial ischemia-reperfusion (IR) injury is a critical complication following revascularization therapy for ischemic heart disease. Itaconate, a macrophage-derived metabolite, has been implicated in inflammation and metabolic regulation. This study investigates the protective role of itaconate derivatives against IR injury.
View Article and Find Full Text PDFBackground: Minimally invasive coronary artery bypass grafting (MICS-CABG) is frequently used for coronary revascularization, but the comparison of long-term clinical results with percutaneous coronary intervention (PCI) in left main disease (LMDs) remains unclear. The present study sought to determine the long-term outcomes of MICS-CABG and PCI in patients with LMDs.
Methods: A total of 551 consecutive patients [man: 457 (82.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!