Objective: Dural replacements are used in cranial surgery when primary closure of native dura is not possible. The goal is to recreate a watertight barrier to prevent cerebrospinal fluid leakage with few associated complications. We reviewed a single-institution experience with a variety of dural substitutes in posterior fossa neurosurgery, for which higher complication rates are well described.
Methods: Patients were screened for suboccipital posterior fossa neurosurgery between November 2005 and April 2007. Surgical logs were reviewed for diagnosis, procedure, and use of dural replacement. Clinical courses were reviewed for hydrodynamic complications, including delayed hydrocephalus, clinically significant pseudomeningocele, aseptic meningitis, and persistent cerebrospinal leakage.
Results: One hundred twenty-eight patients were included, and a dural replacement was used in 106. Overall, the complication rate was 21.9% (28 patients). Complications were seen for acellular human dermis in 33.3%, for collagen matrix in the original formulation in 18.2%, for the reformulation in 16.9%, for the suturable formulation in 50%, for nonautologous materials in 24%, and for no dural replacement in 16.7%. Univariate and multivariate analysis demonstrated that hydrodynamic complications were associated with use of the suturable collagen matrix (odds ratio, 10.8; 95% confidence interval, 2.5-46.1; P = 0.0014) and trended with use of acellular human dermis (odds ratio, 4.6; 95% confidence interval, 0.9-23.1; P = 0.06).
Conclusion: The increased risk of hydrodynamic complications associated with suboccipital neurosurgery is modified by choice of dural replacement. Similar complication rates were seen for most materials with a variety of primary abnormalities, with the exception of suturable bovine collagen matrix, with hydrodynamic complications in 50% of patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1227/01.NEU.0000334414.79963.59 | DOI Listing |
J Med Case Rep
December 2024
UZ Leuven, Plastic, Reconstructive and Aesthetic Surgery, Herestraat 49, 3000, Louvain, Belgium.
Background: NeoDura (Medprin Biotech Gmbh) is an absorbable dural repair patch consisting of degradable poly-L-lactic acid and porcine gelatin that provides a hermetic closure of the dura mater (Medprin Biotech. Neodura. Dural Repair Patch [Brochure].
View Article and Find Full Text PDFActa Biomater
December 2024
Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, PR China; Frontiers Science Center for Synthetic Biology, Key Laboratory of Systems Bioengineering(MOE), Tianjin University, Tianjin 300072, PR China. Electronic address:
The dura trauma or large defects due to neurosurgical procedures can result in potential complications. Dural replacements have proven effective to reduce the risk of seizures, meningitis, cerebrospinal fluid leakage, cerebral herniation, and infection. Although various artificial dural patches have been developed, addressing iatrogenic infections and cerebral adhesions resulting from patches implantation remains a challenge.
View Article and Find Full Text PDFNeuroimaging Clin N Am
February 2025
Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University Medical Center, Center for Academic Medicine, Stanford University Center for Academic Medicine; Radiology + MC: 5659, 453 Quarry Road, Palo Alto, CA 94304, USA. Electronic address: https://twitter.com/BryanLanzman.
Despite all the advantages of magnetic resonance (MR) imaging, there still exist contraindications or limitations to its use. Thus, MR imaging has not entirely replaced fluoroscopic or computed tomographic (CT) myelography to depict the outline of the spinal cord and its nerve roots after intrathecal injection of contrast medium. The growing recent interest of neuroradiologists to accurately diagnose and treat cerebrospinal fluid leaks has also driven a resurgent need for familiarity with this image-guided procedure.
View Article and Find Full Text PDFAnaesthesia
January 2025
Department of Anesthesiology, Duke University School of Medicine, Durham, NC, USA.
Background: The dural puncture epidural technique is a modification of the combined spinal-epidural technique. Data comparing the two techniques are limited. We performed this randomised study to compare the quality of labour analgesia following initiation of analgesia with the dural puncture epidural vs.
View Article and Find Full Text PDFOrthop Surg
November 2024
Orthopaedic Oncology Center, Department of Orthopedics, Changzheng Hospital, Naval Military Medical University, Shanghai, China.
Objective: Lamina-implantation is gradually becoming the main surgical method for the treatment of intraspinal tumors. Traditional titanium (Ti) internal fixation not only produces artifacts, which affects the observation of tumors and dural sac closure, but also faces the problem of secondary surgical removal. In this study, absorbable material were used in lamina replantation for the first time and was evaluated for its efficacy and safety.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!