Background And Purpose: Periprosthetic bone loss after uncemented femoral hip revision is a matter of concern. We have used a proximally porous- and hydroxyapatite-coated prosthesis (Bi-Metric) in revision since 1989 and now we report the bone changes. This prosthesis is intended to distribute the forces more evenly and to avoid proximal femoral unloading.

Methods: 22 patients were unilaterally reoperated because of aseptic loosening. Only patients with a healthy contralateral hip were included. Mean age at revision was 69 (55-80) years. Bone defects were graded by Gustilo-Pasternak and Endo-Klinik classifications. Clinical assessment was performed with Harris hip score. We used radiographs and dual-energy X-ray absorptiometry to evaluate migration, femoral remodeling, and bone mineral density after 72 (30-158) months.

Results: The mean Harris hip score was 74 (30-100) points at follow-up. Mild thigh discomfort was present in 1 patient and moderate thigh pain in 3 patients. There was no loosening or subsidence. Osteolysis seen at revision had diminished in 19 of the 22 hips at follow-up. We noted a large reduction in bone mineral density. It was most pronounced in Gruen regions 1, 2, 6, and 7.

Interpretation: Revision with this stem is a reliable procedure; however, we noted a large degree of proximal bone loss that could lead to later mechanical complications or fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2823225PMC
http://dx.doi.org/10.1080/17453670902804802DOI Listing

Publication Analysis

Top Keywords

bone loss
12
hip revision
8
harris hip
8
hip score
8
bone mineral
8
mineral density
8
bone
7
revision
6
hip
5
large femoral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!