This paper describes the immobilization of bioactive molecules on titanium based surfaces through a combination of nano-mechanical fixation of nucleic acid anchor strands (ASs) by partial and regioselective incorporation within an anodic oxide layer and their hybridization with complementary strands (CSs) intended to be conjugated to bioactive molecules. We focus on the interaction between the substrate surface and the anchor strands, the integrity of ASs and their hybridization ability. The observed dependence of adsorption on pH suggests that initial interaction of terminally phosphorylated ASs with the substrate surface is mediated by electrostatic interaction. Using ASs labelled with (32)P at different termini, it could be shown that strand breaks occur, which are attributed (i) to the formation of reactive oxygen species during anodic polarization, (ii) the photocatalytic activity of the titanium oxide and (iii) drying effects. Damage to AS could be considerably reduced if the electrolyte contained 5 mol l(-1) ethanol, light was excluded during the experimental procedure, and the number of drying and rewetting steps was minimized. A total surface density of AS of 4.5 pmol cm(-2) was reached and could be hybridized to CS with an efficiency of up to 100%. A non-complementary strand (NS) bound with less than 0.5% of the amount of CS under similar conditions. Therefore, non-specific binding of CS is considered as negligible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2009.01.047DOI Listing

Publication Analysis

Top Keywords

titanium based
8
incorporation anodic
8
anodic oxide
8
bioactive molecules
8
anchor strands
8
substrate surface
8
immobilization oligonucleotides
4
oligonucleotides titanium
4
based materials
4
materials partial
4

Similar Publications

Titanium (Ti)-based materials are favored for hard tissue applications, yet their bioinertness limits their success. This study hypothesizes that functionalizing Ti materials with chitosan nano/microspheres and calcitriol (VD) will enhance their bioactivity by improving cellular activities and mineralization. To test this, chitosan particles were applied uniformly onto Ti surfaces using electrophoretic deposition (EPD) at 20 V for 3 minutes.

View Article and Find Full Text PDF

Synergistic enhancement in ultra-trace thallium(I) removal using the titanium dioxide/biochar composite.

J Environ Manage

January 2025

Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, 510006, China. Electronic address:

Thallium (Tl), recognized for its high toxicity, is subject to stringent international regulations regarding its permissible concentrations at ultra-trace levels. In this study, titanium dioxide (TiO) was integrated with potassium (K)-rich biochar to create TiO/biochar (TiO/BC) composites for synergistic enhancement in ultra-trace Tl(I) removal, focusing on achieving concentration below the rigorous local threshold of 0.1 μg/L for drinking water.

View Article and Find Full Text PDF

This study presents a novel optoporation technique using a titanium-coated TiO microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO microstructure (MS).

View Article and Find Full Text PDF

We employed machine learning (ML) techniques combined with potential-dependent photoelectrochemical impedance spectroscopy (pot-PEIS) to gain deeper insights into the charge transport mechanisms of hematite (α-FeO) photoanodes. By the Shapley Additive exPlanations (SHAP) analysis from the ML model constructed from a small data set (dozens of samples) of electrical parameters obtained from pot-PEIS and the PEC performance, we identified the dominant factors influencing the electron transport to the back contact in the bulk and hole transfer to a solution at the hematite/electrolyte interface. The results revealed that shallow defect states significantly enhance electron transport, while deep defect states impede it, and also one of the surface states enhances the hole transfer to the electrolyte solution.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!