Background: The angiographic view (AGV) image is a new post-processing method that is similar to conventional coronary angiography (CAG). The purpose of this study was to evaluate its accuracy for coronary stenosis detection by 64-detector row computed tomography (CT).
Methods And Results: CT evaluation results of 17 patients were compared with the results of invasive CAG on a coronary segment basis concerning the presence of stenoses>50% diameter reduction. All images of the 3 viewing methods (combination of conventional methods, AGV image alone, and axial images alone) were evaluated in consensus by 3 cardiovascular radiologists. Among 196 assessable segments, invasive CAG showed significant coronary artery stenoses in 44 segments. 43 of 44 lesions were detected with the AGV image, and absence of significant stenosis was correctly identified in 135 of 152 segments (sensitivity 98%; specificity 89%; accuracy 91%; positive predictive value 72%, negative predictive value 99%). The sensitivity of the AGV image was the same as that of conventional methods (98%). There was no significant difference in accuracy between the AGV image (91%) and conventional methods (94%). The accuracy of the AGV image was significantly higher than the axial images alone (78%).
Conclusions: AGV image shows promise as a post-processing method for identifying coronary artery stenosis with high accuracy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1253/circj.cj-08-0798 | DOI Listing |
Stroke
January 2025
Department of Radiology (M.G., J.M.O.), Cumming School of Medicine, University of Calgary, AB, Canada.
Cerebral ischemic injury occurs when blood flow drops below a critical level, resulting in an energy failure. The progressive transformation of hypoperfused viable tissue, the ischemic penumbra, into infarction is a mechanism shared by patients with ischemic stroke if timely reperfusion is not achieved. Yet, the pace at which this transformation occurs, known as the infarct growth rate (IGR), exhibits remarkable heterogeneity among patients, brain regions, and over time, reflecting differences in compensatory collateral flow and ischemic tolerance.
View Article and Find Full Text PDFInt Ophthalmol
September 2024
Haydarpaşa Numune Education and Research Hospital, Sadik Eratik Eye Institute, Division of Glaucoma, University of Health Sciences, Istanbul, Turkey.
Jpn J Ophthalmol
May 2024
Department of Ophthalmology, University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey.
Purpose: To evaluate the changes in thickness of tissues, specifically the pericardium patch graft (PPG) covering the silicone tube in Ahmed Glaucoma Valve (AGV) surgery.
Study Design: Prospective observational study.
Methods: This study included cases with refractory glaucoma that underwent AGV implantation with PPG coverage.
Am J Vet Res
May 2024
Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Republic of Korea.
Objective: To assess the characteristics of blebs formed after Ahmed glaucoma valve (AGV) surgery in dogs using ultrasound biomicroscopy (UBM) and to analyze their correlation with postoperative intraocular pressure (IOP).
Animals: 16 eyes (13 dogs) were diagnosed with primary angle-closure glaucoma and were followed up after AGV surgery from June 2021 to September 2023.
Methods: In this prospective study, UBM examinations were performed to assess bleb characteristics, including bleb wall thickness and reflectivity.
Am J Ophthalmol Case Rep
March 2024
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, Japan.
Purpose: This study aims to present two different types of giant bleb formation following Ahmed Glaucoma Valve (AGV) implantation: an anterior enlarged giant bleb and a posterior enlarged giant bleb.
Observations: In Case 1, a 70-year-old Japanese male underwent AGV implantation for neovascular glaucoma in his right eye (OD). Preoperatively, the patient's intraocular pressure (IOP) and best corrected visual acuity (BCVA) were 23 mmHg and 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!