Configuration of the circle of Willis, direction of flow, and shape of the aneurysm as risk factors for rupture of intracranial aneurysms.

J Neurol

Dept. of Neurology, Rudolf Magnus Institute of Neuroscience, Room H02.128, University Medical Centre Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands.

Published: January 2009

Background: Improved knowledge on risk factors for rupture of intracranial aneurysms may lead to more tailored aneurysm management. We studied whether configuration of the circle of Willis, direction of flow towards the aneurysm, and shape of the aneurysm are risk factors for rupture.

Methods: We reviewed CT angiograms of 126 patients with 75 ruptured and 75 unruptured aneurysms, matched for site of the aneurysm, gender and age of the patient, and year of CT angiogram. For the characteristics studied, we calculated odd ratios (ORs) with corresponding 95% confidence intervals (CIs) for risk of rupture. Configuration of the circle of Willis (incompleteness, asymmetry or dominance) was analyzed on a per site basis. Non-spherical shape was subdivided into elliptical (oval and oblong) and multilobed. In additional analyses, we adjusted for size by means of multivariable logistic regression.

Results: Flow straight into the aneurysm (OR 2.0; 95% CI 1.0-4.1) and non-spherical shape (OR 2.8; 95% CI 1.5-5.5) were associated with rupture. Both elliptical shape, with increasing ORs for oval (OR 1.8; 95% CI 0.8-4.0) to oblong shape (OR 6.2; 95% CI 1.9-21), and multilobed shape (OR 4.1; 95% CI 1.2-14) were associated with rupture. These ORs decreased after adjustment for size. Configuration of the circle of Willis was not associated with a strong risk of rupture; moderate risk could not be excluded.

Conclusion: Direction of flow into the aneurysm and nonspherical (both elliptical and multilobed) shape may contribute to the risk of rupture, but are related to aneurysm size and may warrant more frequent follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00415-009-0028-xDOI Listing

Publication Analysis

Top Keywords

configuration circle
16
circle willis
16
direction flow
12
risk factors
12
risk rupture
12
shape 95%
12
willis direction
8
shape
8
aneurysm
8
shape aneurysm
8

Similar Publications

Morphologic study of patent ductus arteriosus based on computed tomography data in 25 dogs.

Front Vet Sci

December 2024

Department of Veterinary Clinical Science, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Republic of Korea.

Introduction: The objective of this study is to analyze the morphology and measurement dimensions of patent ductus arteriosus (PDA) based on computed tomography images.

Methods: The present study retrospectively evaluated computed tomography angiography data from 25 client-owned dogs diagnosed with PDA. PDA was reconstructed based on the central axis and the minimum diameter, ampulla diameter, angle, ampulla cross-section area, and length values were measured at specific measurement sites.

View Article and Find Full Text PDF

Dimensions of bony Kambin's triangle pertaining to endoscopic procedure.

Med J Armed Forces India

December 2024

Senior Consultant (Neurology), NH MMI Superspeciality, Raipur, Chhattisgarh, India.

Background: Endoscopic procedures nowadays are successful, minimally invasive, and safer, with fewer intraoperative and postoperative complications and shorter hospital stays. Kambin's triangle (KT) is the three-dimensional configuration that is used as a transforaminal anatomical corridor for epidural steroid injections and endoscopic surgeries for various lumbar pathologies. This study aims to estimate the dimensions of KT and diameter of the cannula for the transforaminal surgical approaches using KT in the Chhattisgarh population.

View Article and Find Full Text PDF

This paper compares three automated path-planning algorithms based on publicly available data. The algorithms include a Dijkstra-based algorithm (DBA) that improves on the straightforward application of Dijkstra's algorithm, which restricts the path only to the grid edges. We present a fair and comprehensive comparison method for evaluating multiple algorithms-DBA, the Fast Marching Method (FMM), and a great circle-based method.

View Article and Find Full Text PDF

This paper introduces a novel slit-less wavelength-dispersive spectrometer design that incorporates a single-bounce monocapillary with the goal of positioning the sample directly on the Rowland circle, thereby eliminating the need for a traditional entrance slit. This configuration enhances photon throughput while preserving energy resolution, demonstrated in comparative measurements on boron nitride and different lithium nickel manganese cobalt oxide cathodes. A common alternative to an entrance slit for limiting the source size on the Rowland circle is a customized design of the beamline involving a focusing optics unit consisting of two Kirkpatrick-Baez mirrors close to the end station.

View Article and Find Full Text PDF
Article Synopsis
  • - This research introduces a new type of photonic crystal called annular photonic crystals (APCs) designed for real-time detection of calcium carbonate scale in water pipelines.
  • - The sensor uses a circular layout of porous silicon with a central defect layer to monitor changes in refractive index, which indicates scale formation, and employs a modified transfer matrix method for analyzing reflectance.
  • - After extensive optimization of design parameters, the sensor achieved impressive performance metrics, including a QF of 1215 and high sensitivity, making it an efficient, cost-effective, and compact solution for monitoring scale buildup in water systems.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!