Coronary embolism due to atherosclerotic debris is a rather common cause of post-procedural complications. While evidence has shown that both arteriolar vasodilators and platelet glycoprotein inhibitors have proven ineffective against post- and peri-procedural embolism,5 mechanical interventional devices have been shown to improve (lower) 30-day MACE rates. These interventions include distal filtration, distal, and proximal occlusion balloons. The distal occlusion balloon was the first approach to embolic protection. The intervention involves placement of a low pressure (<2 atm) balloon distal to the lesion of interest. Antegrade flow is temporarily interrupted while the lesion is treated. Mounted on conventional 0.014-inch guidewire shafts, distal filtration systems follow a similar intervention method to distal occlusion. In this proceeding, a delivery/recovery sheath catheter deploys an expandable filter device approximating the lumen, which is later removed following PTCA or stent placement in retroversion. The variety of existing, rather novel filter designs typically feature a wire mounted umbrella-type filter consisting of laser-drilled micropores design varied, averaging approximately 100 microm. The primary benefit derived of distal filtration includes the trivial uninterruption of antegrade flow. Unlike distal occlusion, proximal devices allow for vessel protection before lesion crossing, a great advantage in cases involving thrombosis, vulnerable plaque, or primary unstable angina. Proximal occlusion follows a nearly identical implementation as distal occlusion. While substantial research is still needed, interventionalists are advised to always use embolic protection devices in SVG interventions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

embolic protection
8
overview modern
4
modern embolic
4
protection percutaneous
4
percutaneous coronary
4
coronary intervention
4
intervention coronary
4
coronary embolism
4
embolism atherosclerotic
4
atherosclerotic debris
4

Similar Publications

Background: Current guidelines recommend transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis and porcelain aorta (PA). Neurological outcomes of patients with PA undergoing TAVI with modern valves require clarification as most trials examined balloon-expandable valves (BEV) and self-expandable valves in intermediate or high-risk patients, but not specifically in patients with PA. Our aim was to compare outcomes, including stroke and mortality, in well-matched patients with and without PA who received BEV during transfemoral TAVI procedures.

View Article and Find Full Text PDF

Introduction: Atrial fibrillation (AF), a common heart rhythm abnormality, is linked to a higher risk of stroke. Traditionally, warfarin has been the primary anticoagulation treatment for reducing the stroke risk. The new standard of treatment by direct oral anticoagulants (DOACs) offers greater benefits including improved efficacy and fewer adverse effects with reduced monitoring.

View Article and Find Full Text PDF

Background: Cerebral hyperperfusion syndrome (CHS) is a rare but serious complication after carotid artery revascularization. This study aims to determine the impact of carotid artery stenting (CAS) modality on the incidence, severity and overall outcomes of CHS after carotid revascularization.

Methods: Data from patients who underwent CAS with either distal embolic protection (CAS+DEP) or transcarotid artery revascularization (TCAR) were obtained from the Vascular Quality Initiative (VQI) database 2016-2023.

View Article and Find Full Text PDF

Statin Use is Associated with Decreased Venous Thromboembolism Events Following Total Hip Arthroplasty: A Matched Retrospective Cohort Study.

J Arthroplasty

January 2025

Department of Orthopedic Surgery, NYU Langone Health, 301 E 17th St, New York, NY, USA, 10010. Electronic address:

Background: Despite advances in surgical techniques and postoperative prophylactic protocols, venous thromboembolism (VTE) events remain an important source of morbidity following total hip arthroplasty (THA). Prior research in cardiology and other surgical fields has suggested that statin medications may have a protective effect against VTE. Our study aimed to: 1) Assess if preoperative statin use was associated with decreased rates of VTE following THA, and 2) conduct a subgroup analysis of statin intensity and VTE events.

View Article and Find Full Text PDF

Acute coronary occlusion during transcatheter aortic valve implantation (TAVI) is an unwarranted complication associated with high mortality. The current TAVI practices recommend a multidetector computed tomography (MDCT) evaluation of the aortic valve, the left ventricular outflow tract, and the aortic root to determine the conventional risk factors for coronary obstruction like low-lying coronary ostia and narrow sinuses of Valsalva, mandating prophylactic coronary protection or native valve leaflet modification in high-risk patients. Despite optimal anatomy, acute coronary occlusion can still occur due to multiple mechanisms, one of which is coronary embolism due to thrombus, calcium, or native aortic valve fragments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!