A suitable three potential-time waveforms for the electrochemical detection of 2-deoxy-2-chloro-d-glucose (ClDG) by gold working electrode and palladium reference electrode have been developed and method validation was performed on Waters 2796 Bioalliance HPLC system coupled with pulsed amperometric detection (HPLC/PAD). FDG and ClDG could be completely separated by 50 mM NaOH mobile phase at a flow rate of 1.0 ml/min; 30 degrees C analytical column temperature; and E1 of 200 mV, T1 of 900 mS; E2 of -770 mV, T2 of 10 mS; E3 of 1400 mV, T3 of 10 mS; acquisition delay (AD) of 300 mS. The validation results were shown as follows: (1) in specificity study, mannose, FDG and ClDG could be completely separated and the retention times of these were 6.2, 11.1 and 13.5 min, respectively, with a total run time of 20 min; (2) the intraday repeatable precision expressed with the CV% in six successive analysis was 0.52% (for FDG) and 0.83% (for ClDG); (3) the interday variability precision expressed with the CV% value of the repeatable precision of 3 days was 0.99%, 0.52% and 0.58% for FDG and 0.71%, 0.83% and 1.24% for ClDG; both the CV% of intraday and interday reproducibilities of FDG and ClDG were better than 1.5%; (4) the accuracy and recovery of FDG and ClDG expressed with the percentage of mean value of three successive analysis were 99.75% (for FDG) and 100.68% (for ClDG) which were all greater than 95%; (5) under optimum conditions, the limit of detection of FDG and ClDG was 0.41 and 0.68 microg/ml, and the limit of quantization of FDG and ClDG was 1.24 and 2.04 microg/ml; (6) the correlation coefficient (r) value of linearity is over 0.999 by 5-50 microg/ml ranges of both compounds, respectively; (7) no interference peak effects by composition of mobile phase or increasing/decreasing flow rate or change of temperature was observed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nucmedbio.2008.11.008DOI Listing

Publication Analysis

Top Keywords

fdg cldg
24
cldg
10
fdg
9
three potential-time
8
potential-time waveforms
8
amperometric detection
8
cldg completely
8
completely separated
8
mobile phase
8
flow rate
8

Similar Publications

Prognostic value of metabolic variables of [18F]FDG PET/CT in surgically resected stage I lung adenocarcinoma.

Medicine (Baltimore)

September 2017

Department of Diagnostic Radiology PET/CT Center Department of Thoracic Surgery, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

The objective of this study was to assess the prognostic value of metabolic tumor burden measured by positron emission tomography/computed tomography (PET/CT) in patients with stage I lung adenocarcinoma.We reviewed 127 consecutive patients with pathologically proven stage I lung adenocarcinoma who underwent pretreatment [18F]FDG PET/CT scans in our hospital from 2005 June to 2012 June. The maximum, mean, and peak standardized uptake value (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), and computed tomography volume (CTV) were measured.

View Article and Find Full Text PDF

A suitable three potential-time waveforms for the electrochemical detection of 2-deoxy-2-chloro-d-glucose (ClDG) by gold working electrode and palladium reference electrode have been developed and method validation was performed on Waters 2796 Bioalliance HPLC system coupled with pulsed amperometric detection (HPLC/PAD). FDG and ClDG could be completely separated by 50 mM NaOH mobile phase at a flow rate of 1.0 ml/min; 30 degrees C analytical column temperature; and E1 of 200 mV, T1 of 900 mS; E2 of -770 mV, T2 of 10 mS; E3 of 1400 mV, T3 of 10 mS; acquisition delay (AD) of 300 mS.

View Article and Find Full Text PDF

A sensitive quality control method is often required in positron emission tomography (PET) radiopharmaceutical analysis due to the high specific radioactivity of synthetic products. The applicability of a radio high-performance liquid chromatography (HPLC) method with fluorescence detection was evaluated for a wide variety of PET radiopharmaceuticals. In 29 different radiopharmaceuticals studied, 20 compounds exhibited native fluorescence.

View Article and Find Full Text PDF

No-carrier-added 2-[(34m)Cl]chloro-2-deoxy-d-glucose ([(34m)Cl]ClDG) was prepared via nucleophilic displacement reaction of 1, 3, 4, 6-tetra-O-acetyl-2-trifluoromethansulfonyl mannose with K[(34m)Cl]Cl/kryptofix 222 complex using (34m)Cl(-) produced via the (nat)S(alpha, 2n) nuclear reactions. The synthesis time from enrichment of [(34m)Cl]Cl(-) was approximately 45min and the radiochemical yield was 79.6+/-6.

View Article and Find Full Text PDF

A practical, sensitive and rapid analytical method was established and validated for chemical impurity tests of 2-deoxy-2-fluoro-d-glucose (FDG), 2-deoxy-2-chloro-d-glucose (ClDG) and Kryptofix 2.2.2 (K-222) in [18F]FDG.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!