The objective of the study was to evaluate the reproducibility and repeatability of the combined use of the hyperinsulinemic-euglycemic (H-E) clamp and tracer dilution techniques. Ten nondiabetic men underwent a low-dose (40 mU/[m(2) min]) H-E clamp that was repeated within 3 to 4 days using porcine or human insulin in a double-blinded, randomized, crossover design. Coefficients of variation (CVs) for intraindividual differences and repeatability coefficient were calculated to evaluate reproducibility and repeatability. The Bland and Altman method was used to quantify repeatability. The CVs for intraindividual differences were 5.7% +/- 3.5% for steady-state (SS) insulin; 6.7% +/- 6.2% and 54.2 +/- 38.3% for basal and SS endogenous glucose product (EGP), respectively; and 10.3% +/- 8.5% for total insulin-stimulated glucose disposal (M) values. Basal EGP, SS EGP, and SS glucose and insulin concentrations were similar for the 2 clamps; but glucose infusion rate (P = .02) and M (borderline significant, P = .06) were higher in the first clamp than the second clamp. No significant correlations between mean of differences and average of basal and SS EGP, SS insulin concentration, and M between the 2 clamps were observed. We also found that the different values were less than the repeatability coefficients of these parameters and that the 95% limits of agreement and the interval of repeatability coefficient of these parameters were similar. There were no differences in metabolic responses between clamps when compared by the type of insulin (porcine vs human) infused. Our findings indicate that, although SS EGP has a high CV, the clamp, which measures insulin action (ie, SS insulin, M), and the tracer dilution technique for assessing basal EGP are repeatable and reproducible. Decreased glucose infusion rate and M over a short period in the second clamp may reflect an accumulative effect of continued physical inactivity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2692526 | PMC |
http://dx.doi.org/10.1016/j.metabol.2008.09.029 | DOI Listing |
Ophthalmol Sci
October 2024
Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, New Jersey.
Objective: To investigate retinal vascular permeability mapping as a potential biomarker for diabetic retinopathy in subjects with diabetes with no signs of retinopathy and with mild nonproliferative retinopathy.
Design: This is a case-control study.
Subjects: Participants included 7 healthy controls, 22 subjects with diabetes mellitus and no clinical signs of retinopathy (DMnoDR), and 7 subjects with mild nonproliferative diabetic retinopathy (NPDR).
Mikrochim Acta
December 2024
Department of Analytical Chemistry and Food Technology, Environmental Sciences Institute (ICAM), University of Castilla-La Mancha, Avda. Carlos III S/N, 45071, Toledo, Spain.
Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a powerful tool for metallic nanoparticle (NP) characterisation in terms of concentration and, taking into account several assumptions, also size. However, this technique faces challenges, such as the intrinsic matrix effect, which significantly impact the results when analysing real complex samples. This issue is critical for the calculations of key SP-ICP-MS parameters ultimately altering the final outcomes.
View Article and Find Full Text PDFPhys Med Biol
December 2024
Massachusetts General Hospital Athinoula A Martinos Center for Biomedical Imaging, 149 13th Street, Charlestown, Massachusetts, 02129, UNITED STATES.
Magnetic Particle Imaging (MPI) was introduced in 2005 as a promising, tracer-based medical imaging modality with the potential for high sensitivity and spatial resolution. Since then, numerous preclinical devices have been built but only a few human-scale devices, none of which targeted functional neuroimaging. In this work, we probe the challenges of scaling the technology to meet the needs of human functional neuroimaging with sufficient sensitivity for detecting the hemodynamic changes following brain activation with a spatio-temporal resolution comparable to current functional Magnetic Resonance Imaging (fMRI) approaches.
View Article and Find Full Text PDFMaterials (Basel)
October 2024
Centre for Advanced Materials Joining (CAMJ), Department of Mechanical and Mechatronic Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada.
Laser welding was performed using different filler wires, ER70S steel, commercially pure iron, and pure nickel filler, in the context of welding X80 pipeline steel to assess the microstructure and mechanical properties of the weld metal. Introducing an ER70S wire promoted acicular ferrite formation in the fusion zone, compared to a bainitic microstructure in an autogenous laser weld. The use of pure iron wire was considered as a potential strategy for reducing hardenability, as it led to the dilution of alloying elements in the fusion zone, increasing ferrite content and reducing weld metal hardness to a level compliant with API pipeline standards.
View Article and Find Full Text PDFJ Environ Radioact
December 2024
Department of Civil Engineering, Indian Institute of Technology, Kanpur 208016, UP, India. Electronic address:
We present results from the laboratory experiments performed to study the behaviour of dense plumes in porous media using Caesium Nitrate (CsNO) as the solute. Specifically, we consider the case of fixed volume release of a dense fluid into a saturated porous medium of lighter density. Our experiments consider the injection volume and concentration of CsNO and the porous medium permeability as experimental variables.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!