A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of two innovative methods to measure contaminant mass flux in groundwater. | LitMetric

Validation of two innovative methods to measure contaminant mass flux in groundwater.

J Contam Hydrol

Air Force Institute of Technology, 2950 Hobson Way, Building 640, AFIT/ENV, Wright Patterson Air Force Base, OH 45433-7765, USA.

Published: April 2009

The ability to quantify the mass flux of a groundwater contaminant that is leaching from a source area is critical to enable us to: (1) evaluate the risk posed by the contamination source and prioritize cleanup, (2) evaluate the effectiveness of source remediation technologies or natural attenuation processes, and (3) quantify a source term for use in models that may be applied to predict maximum contaminant concentrations in downstream wells. Recently, a number of new methods have been developed and subsequently applied to measure contaminant mass flux in groundwater in the field. However, none of these methods has been validated at larger than the laboratory-scale through a comparison of measured mass flux and a known flux that has been introduced into flowing groundwater. A couple of innovative flux measurement methods, the tandem circulation well (TCW) and modified integral pumping test (MIPT) methods, have recently been proposed. The TCW method can measure mass flux integrated over a large subsurface volume without extracting water. The TCW method may be implemented using two different techniques. One technique, the multi-dipole technique, is relatively simple and inexpensive, only requiring measurement of heads, while the second technique requires conducting a tracer test. The MIPT method is an easily implemented method of obtaining volume-integrated flux measurements. In the current study, flux measurements obtained using these two methods are compared with known mass fluxes in a three-dimensional, artificial aquifer. Experiments in the artificial aquifer show that the TCW multi-dipole and tracer test techniques accurately estimated flux, within 2% and 16%, respectively; although the good results obtained using the multi-dipole technique may be fortuitous. The MIPT method was not as accurate as the TCW method, underestimating flux by as much as 70%. MIPT method inaccuracies may be due to the fact that the method assumptions (two-dimensional steady groundwater flow to fully-screened wells) were not well-approximated. While fluxes measured using the MIPT method were consistently underestimated, the method's simplicity and applicability to the field may compensate for the inaccuracies that were observed in this artificial aquifer test.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jconhyd.2009.01.001DOI Listing

Publication Analysis

Top Keywords

mass flux
20
mipt method
16
flux groundwater
12
tcw method
12
artificial aquifer
12
flux
11
method
9
measure contaminant
8
contaminant mass
8
test mipt
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!