Magnetization transfer enhanced vascular-space-occupancy (MT-VASO) functional MRI.

Magn Reson Med

The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA.

Published: April 2009

Vascular-space-occupancy (VASO) MRI is a novel technique that uses blood signal nulling to detect blood volume alterations through changes in tissue signal. VASO has relatively low signal to noise ratio (SNR) because only 10-20% of tissue signal remain at the time of blood nulling. Here, it is shown that by adding a magnetization transfer (MT) prepulse it is possible to increase SNR either by attenuating the initial tissue magnetization when the MT pulse is placed before inversion, or, accelerating the recovery process when the pulse is applied after the inversion. To test whether the MT pulse would affect the blood nulling time in VASO, MT effects in blood were measured both ex vivo in a bovine blood phantom and in vivo in human brain. Such effects were found to be sufficiently small (<2.5%) under a saturation power or=40 ppm to allow use of the same nulling time. Subsequently, functional MRI experiments using MT-VASO were performed in human visual cortex at 3 Tesla. The relative signal changes in MT-VASO were of the same magnitude as in VASO, while the contrast to noise ratio (CNR) was enhanced by 44+/-12% and 36+/-11% respectively. Therefore, MT-VASO should provide a means for increasing inherently low CNR in VASO experiments while preserving the CBV sensitivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2728078PMC
http://dx.doi.org/10.1002/mrm.21911DOI Listing

Publication Analysis

Top Keywords

magnetization transfer
8
tissue signal
8
blood nulling
8
blood
6
transfer enhanced
4
enhanced vascular-space-occupancy
4
vascular-space-occupancy mt-vaso
4
mt-vaso functional
4
functional mri
4
mri vascular-space-occupancy
4

Similar Publications

The functional properties of tetraaryl compounds, M(aryl) (M = transition metal or group 14 element), are dictated not only by their common tetrahedral geometry but also by their central atom. The identity of this atom may serve to modulate the reactivity, electrochemical, magnetic, and optical behavior of the molecular species, or of extended materials built from appropriate tetraaryl building blocks, but this has not yet been systematically evaluated. Toward this goal, here we probe the influence of Os(IV), C, and Si central atoms on the spectroelectrochemical properties of a series of redox-active tetra(ferrocenylaryl) complexes.

View Article and Find Full Text PDF

Degradation of Methylene Blue by Ozone Oxidation Catalyzed by the Magnetic MnFeO@CoS Nanocomposite.

Langmuir

January 2025

CSSC Nanjing Lvzhou Environmental Protection Co., Ltd, Nanjing 210039, China.

In this study, the MnFeO@CoS magnetic nanocomposite was prepared by a two-step hydrothermal method and used to catalyze the ozone oxidation degradation of methylene blue. It was characterized by XRD, EDS, SEM, FT-IR, and XPS. The results showed that the introduction of CoS made MnFeO grow uniformly on CoS nanosheets, which effectively prevented the agglomeration of MnFeO.

View Article and Find Full Text PDF

Circulating and Magnetic Resonance Imaging Biomarkers of Intestinal Fibrosis in Small Bowel Crohn's Disease.

Inflamm Bowel Dis

January 2025

Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH, USA.

Background: We previously identified circulating and MRI biomarkers associated with the surgical management of Crohn's disease (CD). Here we tested associations between these biomarkers and ileal resection inflammation and collagen content.

Methods: Fifty CD patients undergoing ileal resection were prospectively enrolled at 4 centers.

View Article and Find Full Text PDF

Comparative Sensitivity of MRI Indices for Myelin Assessment in Spinal Cord Regions.

Tomography

January 2025

Laboratory for Biomarker Imaging Science, Graduate School of Biomedical Science and Engineering, Hokkaido University, N15 W7, Kita-ku, Sapporo 060-8638, Japan.

Although multiple magnetic resonance imaging (MRI) indices are known to be sensitive to the noninvasive assessment of myelin integrity, their relative sensitivities have not been directly compared. This study aimed to identify the most sensitive MRI index for characterizing myelin composition in the spinal cord's gray matter (GM) and white matter (WM). MRI was performed on a deer's ex vivo cervical spinal cord.

View Article and Find Full Text PDF

Fast Hadamard-Encoded 7T Spectroscopic Imaging of Human Brain.

Tomography

January 2025

NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.

: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!