Purpose: Favorable dosimetric results have been reported using intraoperative inverse optimization (IO) for permanent prostate brachytherapy. The clinical implications of these improvements in dosimetry are unclear. We review toxicity and early biochemical outcomes for patients implanted using IO technique.

Methods And Materials: Between 2001 and 2007, 165 patients received permanent prostate implants using real-time IO and had >/=3 months of followup. Dose constraints for inverse planning were: the prostate volume receiving 100% of the prescription dose [prostate V(100)] was >95%; the dose received by 90% of the gland [prostate D(90)] was within the 140-180 by dose range; the volume of urethra receiving 150% of the prescription dose [urethra V(150)] was <30%; and the volume of rectal wall receiving 110% of the prescription dose [rectal V(110)] was <1.0 cc. Toxicity was prospectively scored using the Radiation Therapy Oncology Group toxicity scale and the International Prostate Symptom Score questionnaire. Biochemical control was determined using the nadir + 2 ng/mL definition.

Results: Mean followup was 30 months (range, 6-63 months). Risk classification was low risk in 89% and intermediate risk in 11%. Iodine-125 sources were used for 161 implants and palladium-103 sources for four implants. The median number of seeds and total activity implanted were 61 and 999 MBq, respectively, for a median prostate volume of 33.6 cc. Late GU and GI morbidity was uncommon. Among patients with at least 24 months followup, 16% had persistent Grade 2-3 urinary morbidity. Grade 2 rectal bleeding occurred in 1 patient (0.6%). Biochemical failure has occurred in only 4 patients at last followup.

Conclusions: IO technique for prostate brachytherapy is associated with low rates of late morbidity and excellent early biochemical control. Additionally, the number of seeds and total implanted activity required to achieve a high-quality implant are lower compared with historical controls.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brachy.2008.12.004DOI Listing

Publication Analysis

Top Keywords

inverse optimization
8
prostate brachytherapy
8
permanent prostate
8
prescription dose
8
dose
5
favorable toxicity
4
toxicity biochemical
4
biochemical control
4
control real-time
4
real-time inverse
4

Similar Publications

Large library docking of tangible molecules has revealed potent ligands across many targets. While make-on-demand libraries now exceed 75 billion enumerated molecules, their synthetic routes are dominated by a few reaction types, reducing diversity and inevitably leaving many interesting bioactive-like chemotypes unexplored. Here, we investigate the large-scale enumeration and targeted docking of isoquinuclidines.

View Article and Find Full Text PDF

Inverse design of promising electrocatalysts for CO reduction via generative models and bird swarm algorithm.

Nat Commun

January 2025

Key Laboratory of Quantum Materials and Devices of Ministry of Education, School of Physics, Southeast University, Nanjing, 21189, China.

Directly generating material structures with optimal properties is a long-standing goal in material design. Traditional generative models often struggle to efficiently explore the global chemical space, limiting their utility to localized space. Here, we present a framework named Material Generation with Efficient Global Chemical Space Search (MAGECS) that addresses this challenge by integrating the bird swarm algorithm and supervised graph neural networks, enabling effective navigation of generative models in the immense chemical space towards materials with target properties.

View Article and Find Full Text PDF

Background: As percutaneous therapeutic options expand, the optimal management of severe aortic stenosis (AS) and concomitant coronary artery disease (CAD) is being questioned between coronary artery bypass grafting and surgical aortic valve replacement (CABG+SAVR) versus percutaneous coronary intervention and transcatheter aortic valve replacement (PCI+TAVR). We sought to compare perioperative and longitudinal risk-adjusted outcomes between patients undergoing CABG+SAVR versus PCI+TAVR.

Methods: Using the United States Centers for Medicare and Medicaid Services inpatient claims database, we evaluated all patient age 65 and older with AS and CAD undergoing CABG+SAVR or PCI+TAVR (2018-2022).

View Article and Find Full Text PDF

Multi-objective design of multi-material truss lattices utilizing graph neural networks.

Sci Rep

January 2025

Advanced Manufacturing Lab, ETH Zürich, Leonhardstrasse 21, 8092, Zurich, Switzerland.

The rapid advancements in additive manufacturing (AM) across different scales and material classes have enabled the creation of architected materials with highly tailored properties. Beyond geometric flexibility, multi-material AM further expands design possibilities by combining materials with distinct characteristics. While machine learning has recently shown great potential for the fast inverse design of lattice structures, its application has largely been limited to single-material systems.

View Article and Find Full Text PDF

Association between intraoperative fluid management and postoperative outcomes in living kidney donors: a retrospective cohort study.

Sci Rep

January 2025

Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

Optimal fluid strategy for laparoscopic donor nephrectomy (LDN) remains unclear. LDN has been a domain for liberal fluid management to ensure graft perfusion, but this can result in adverse outcomes due to fluid overload. We compared postoperative outcome of living kidney donors according to the intraoperative fluid management.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!