A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modeling solvent evaporation during the manufacture of controlled drug-release coatings and the impact on release kinetics. | LitMetric

Modeling solvent evaporation during the manufacture of controlled drug-release coatings and the impact on release kinetics.

J Biomed Mater Res B Appl Biomater

Division of Chemistry and Materials Science, Office of Science and Engineering Laboratories, Center for Device and Radiological Health, Food and Drug Administration, Silver Spring, Maryland 20903, USA.

Published: August 2009

To improve functionality and performance, controlled drug-release coatings comprised of drug and polymer are integrated with traditional medical devices, e.g., drug eluting stents. Depending on manufacturing conditions, these coatings can exhibit complex microstructures. Previously, a thermodynamically consistent model was developed for microstructure evolution in these systems to establish relationships between process variables, microstructure, and the subsequent release kinetics. Calculations based on the model were, in general, consistent with experimental findings. However, because of assumptions regarding the evaporation of solvent during fabrication, the model was unable to capture variations through the coating thickness that are observed experimentally. Here, a straightforward method is introduced to incorporate solvent evaporation explicitly into the model. Calculations are used to probe the impact of solvent evaporation rate and drug loading on the microstructure that forms during manufacturing and subsequent drug release kinetics. The predicted structures and release kinetics are found to be consistent with experimental observations. Further, the calculations demonstrate that solvent evaporation rate can be as critical to device performance as the amount of drug within the coating. For example, changes of a factor of five in the amount of drug released were observed by modifying the rate of solvent evaporation during manufacturing.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.31336DOI Listing

Publication Analysis

Top Keywords

solvent evaporation
20
release kinetics
16
controlled drug-release
8
drug-release coatings
8
consistent experimental
8
evaporation rate
8
amount drug
8
evaporation
6
drug
6
solvent
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!